15.3.10 Environment

For indoors and outdoors installation
Operating temperature
• Continuous functioning: from -40°C (-40°F) up
to +60°C (140°F) (+65°C (149°F) for versions with
320x256 sensor)
• Temperature test complies with NEMA-TS 2-2003
(R2008) par. 2.1.5.1, test profile fig. 2-1 (from -34°C
(-29.2°F) to +74°C (165.2°F)) (only for versions with
320x256 sensor)
• De-icing function intervention: from -40°C (-40°F)
up to -10°C (14°F)
Wind resistance
• PTZ camera static: 230km/h (143mph) max.
• PTZ camera moving, at the maximum speed:
230km/h (143mph) max.
Relative humidity: from 5% up to 95%

15.3.11 Certifications

Electrical safety (CE): EN60950-1, IEC60950-1,
EN62368-1, IEC62368-1
Electromagnetic compatibility (CE): EN61000-6-4,
EN50130-4, EN55032 (Class A)
Outdoor installation (CE): EN60950-22, IEC60950-22
IP protection degree (EN60529): IP66, IP67, IP68
Vibration test: EN50130-5, EN60068-2-6
Salty fog resistance: EN50130-5, EN60068-2-52
IK protection degree: IK10 (except glass window and
germanium window)
UL certification (UL60950-1, CAN/CSA C22.2 No.
60950-1-07,UL62368-1 CAN/CSA C22.2 No. 62368-1-
14): cULus Listed
Electromagnetic compatibility (North America): FCC
part 15 (Class A), ICES-003 (Class A)
Level of protection Type (UL50E): 4X, 6P
EAC certification
Restriction of Hazardous Substances (RoHS),
Directive 2011/65/EU
Waste Electrical and Electronic Equipment (WEEE),
Directive 2012/19/EU
46
15.3.12 Certifications - Railway
applications
Compliance to railway application standard:
EN50121-4 (the product requires the filter accessory
SURGEPR)