Key To Alarm Table - Angelo Po FX61 E3 Manuel D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section 8
Troubleshooting

KEY TO ALARM TABLE

Alarm
Fault
No water in chamber, or
H2O
water pressure too low
No water at drain, or water
H2O.
pressure too low
Oven door opening or
OPE
closure request
Indicates that cleaning is
CLE
required
Indicates the need for the
dEC
descaling operation
The cooking chamber probe
E01
has failed or is not properly
connected
The core probe has a failure
E02
or has not been properly
connected
The steam discharge probe
E03
has failed
The motor-operated valve is
E04
not positioned correctly
Safety thermostat failure
E05
Overload cutouts tripped
E06
Power board failure
E07
The optional vacuum probe
E08
has failed or is not properly
connected
88 Combination Oven Installation and Operation Manual
Remedy
Check that mains water is
present or adjust the pressure
(see page 23); if the problem
persists call an authorized
service agent
Check that water supply is
present or adjust the pressure
(see page 23); if the problem
persists call an authorized
service agent
Open or close the oven
door, Call an authorized
service agent if this message
continues to be displayed
Launch an automatic cleaning
cycle
Perform descaling
Call an authorized service
agent
Check the position of the
product core probe or call an
authorized service agent if it is
faulty
Call an authorized service
agent
Switch on the oven again and
if the problem persists call an
authorized service agent
Call an authorized service
agent
Call an authorized service
agent
Call an authorized service
agent
Press the "Reset" button
Notes
Convection cooking cycles can still
be performed
Convection and steam cooking
cycles can still be performed
The cooking cycle does not start
until the door has been opened or
closed as required
The oven's functions are enabled;
cooking cycles can be performed
The oven's functions are enabled
so cooking cycles can be carried
out
The oven's functions are disabled;
no cooking cycles can be
performed
Cooking cycles with product core
probe cannot be performed
Convection and steam cooking
cycles can still be performed
Convection and steam cooking
cycles can still be performed
The oven's functions are disabled;
no cooking cycles can be
performed
The oven's functions are disabled;
no cooking cycles can be
performed
The oven's functions are disabled;
no cooking cycles can be
performed
Disconnect and reconnect the
vacuum probe before starting
the cooking cycle. If the problem
persists, call an authorized service
agent