APPLIANCE INSTALLATION

All installation stages must be considered based
on the site survey and specifi c installation location
of the unit. Before starting these stages, as well
as deciding the place of installation, the person
authorized to perform these operations must
organize a "safety plan" to protect people directly
involved, and must also ensure strict compliance
with all legal requirements, especially those relating
to mobile work-sites.
The location of the installation must have all the
utility supply, ventilation, extraction and production
residue venting connections required. In addition,
the location must be suitably lit and meet all local
health department and hygiene requirements to
prevent the contamination of foods.
It is suggested to mark the location of each individual
appliance or subassembly prior to installation.
Install in accordance with the relevant local codes,
regulations and specifi cations in the country of use.
IMPORTANT _________________________
Install the appliance on a stand (available
as an option) and position it as shown in
the diagram (For version FX61-101-82-122
only).
If the oven is installed in the middle of a room, please
leave at least a distance of 20 inches between its
back and other appliances.
IMPORTANT _________________________
All clearance requirements are the same for
combustible or non-combustible constructions.
Suitable for installation on combustible fl oors.
3.94 in
20
in
18 Combination Oven Installation and Operation Manual

CASTER - MOUNTED OVENS

For an appliance equipped with casters, the
installation must be made with a connector that
complies with the Standard for Connectors for
Movable Gas Appliances, ANSI Z21.69
6.16, and a quick-disconnect device that complies
with the Standard for Quick-Disconnect Devices
for Use With Gas Fuel, ANSI Z21.41
Adequate means must be provided to limit the
movement of the appliance without depending on
the connector and the quick-disconnect device or
its associated piping to limit appliance movement.

ROOM VENTILATION

The room where the appliance is installed must have
air inlets to ensure that the appliance can operate
correctly and provide the necessary air exchange in
the room.
Air inlets must be of appropriate size, protected
by gratings and placed so that they cannot be
obstructed.
3.94 in
CSA
CSA 6.9.