Storch PowerCoat FF Mode D'emploi page 149

Pistolet manuel airless sans fil
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 62
Problem
Material drips or seeps out of
the nozzle after releasing the
trigger
Cause
The spray gun is worn out.
The nozzle filter is partly clogged or dama-
ged.
The nozzle holder is not fully screwed onto
the spray gun.
The seat is worn out.
The needle valve is worn or damaged.
149
Remedy
Replace the spray gun.
Clean or replace the filter; see page 136.
See Page 134.
Replace the spray nozzle.
Replace the needle valve.
Original instruction

Publicité

Table des Matières
loading

Table des Matières