7. PROGRAMMING FUNCTIONS
To log on the programming functions you have to press simultaneously the keys
than 3 seconds.
The programming parameters has been devided in 3 categories: "Trimmer", "Dip-Switches" and "Backups".
Press the keys
("menù up") and
("menù down") to skim through three categories of programming.
Press the key
("enter") to enter the visualized programming.
Then press the keys
("menù up") and
("menù down") to skim through the various parameters.
To modify the visualized parameter, press the key
to decrease it.
To confi rm the value which was set up, press the key
Information
To exit from the programming and to return to the function of SELECTION, you have to press again
the keys
and
for more than 3 seconds.
7.1 PARAMETER CATEGORIES E RELEVANT VALUES
TRIMMER
Parameter
50 OPENING SPEED
51 CLOSING SPEED
52 APPROACHING SPEED
53 STOPPING TIME
54 DELAY NIGHT LOCK
55 STRENGHT PUSH
56 PARTIAL OPENING%
57 STOPPING TIME PARTIAL OPENING
DIP SWITCHES
Parameter
70-PARTIAL OPENING
71- EFFRACTION
72- MASTER-SLAVE
73-EMERGENCY OPENING
74- PHOTO CELL
75 - ANTIPANIC BATTERY
76 - ANTIPANIC
77 - ELECTRIC BLOCK
78 - EMERGENCY
79 - BLACK OUT
80 - NOT USED
and
("plus") to increase the value and the key
("enter"); the new value will be memorized.
Possible values
from 0 to 100%
from 0 to 100%
from -1 to +1
from 0 to 30 seconds
from 0 to 60 seconds
from 1 to 99
from 0 to 99%
from 0 to 30 seconds
Possible values
fi xed or adaptive
free or resists
trained or enabled
fast or slow
normaly opened or normaly closed
enabled or disabled
opens or closes
absent or present
close or open
unlock or don't unlock
81 - EFFRACTION PHARMACY
82 - OPERATING
during more
83 - MAINTENANCE SIGNAL
84 - APPROACHING CLOSED ZONE
85 - NIGHT BLOCK
86 - BEEPER
87 - SPEED LIMIT OF CLOSING
88 - ALWAYS LOCK
("minus")
89 - MAINTENANCE CLOSING FORCE
90 - PHARMACY WIDTH
91 - PRIORITY
92 - PRIORITY
93 - DOOR TYPE
BACKUPS
98-FROM WING
99-TOWARD WING
8. OPERATING IN CONTINUOUS CYCLE
In the back of the keyboard there is the key SW1 whose function is to get the automation enter the continous cycle,
an useful function in case of testing or validation of the automation.
To enter into this phase of automatic cycle, you have to close the door by pressing the key SW1 and to
supply an opening impulse.
From this moment the door begin to operate in continous opening and closing cycle.
Information
To stop the continuous cycle operation it is necessary to RESET, or to press the STOP, or the
EMERGENCY (if theese are installed).
closes or resists
step by step or normal
abled or enabled
fi xed 30 cm or adaptive
shutters blocked or shutters free
enabled or disabled
enabled or disabled
enabled or diabled
enabled or disabled
30 cm or 15 cm
emergency or night lock
antipanic or emergency
one shutter or double shutter
Pressing the key
("enter") all the parameters of the Wing-E
are memorized in the eeprom of the planner
Pressing the key
("enter") all the parameters contained
in the eeprom of the planner will be memorized on Wing-E