3.3 FUNCTIONING PROGRAMMING

It is now possible to program the device.
CAUTION –
Every time you program the device, disconnect the electrical power
supply to cancel the previously set program.
For the settings of the jumper set JP , see 1.1 "Block diagram of the device" - "Set of
jumpers".
AUTOMATIC MODE – When you select automatic functioning and a start pulse is
given, the device commands opening until the end of the work time, the gate stays open
for the pause time selected and then closes automatically.
• If a pulse is given during opening, the control system ignores it and the gate continues
its opening movement.
• If a pulse is given or the photocells are triggered during closing, the gate changes
direction and starts to open.
• If the photocells are triggered during the pause time, the device remains in pause
until the photocells are cleared.
SEMIAUTOMATIC MODE WITH STOP – When you select semiautomatic functioning
when the gate is closed and a start pulse is given, the device commands gate opening
until the end of the work time set. If another start pulse is given during opening, the
gates stop in position until another start pulse is given, which commands closing. A start
pulse given during closing commands re-opening of the gates.
NOTE – In both functioning modes, the motor power supply is cut off by the electronic
control of the current absorption. This occurs when the gates reach the mechanical limit
switch, during opening and closing, or when they come into contact with an obstacle.
ENGLISH
Flashing light output - 24 V output which commands the flashing light.
This output commands the flashing light with a pulsating power supply with frequency
of 1 Hz: the light is ON for 0.5 seconds and OFF for 0.5 sec. If pre-flashing is enabled,
this output is enabled 3 seconds before the command to move the gates (opening and
closing).
NOTE -
Only use Aprimatic ET Series 24V LED flashing lights to avoid a fault with
the output which will cause incorrect functioning of the entire system.
Motor output – The T4Power device has two outputs for independent motors. The output
for motor 1 is the one used to signal the gate closing delay by selecting the relative
trimmer. The output for motor 2, on the other hand, has a fixed opening delay of 1.5
seconds. If the pedestrian start is used (one-wing opening), only the gate connected to
the output for motor 1 will start.
NOTE – If this device is used in gates with only one wing, the motor must be connected
to the output for motor 1.
Battery-charger circuit connection (not supplied) – The T4Power device can be
connected to an auxiliary circuit for controlling an emergency battery unit which can be
used, in the event of a power failure, for emergency purposes (opening/closing). This
circuit, which must be fitted in the same plastic container which houses the T4Power
device, must be connected to the C.B. terminal respecting the polarity indicated.
The battery unit is contained in a separate container and is not supplied with the device.
NOTE – Only use the emergency battery unit supplied by Aprimatic.