Les langues disponibles

REMOTE CONTROL OPERATION TESTS
NOTICE
DO NOT run outboard without a
water supply to the outboard's cooling sys-
tem. Cooling system and/or powerhead dam-
age could occur. Be sure the water intake
screens are below the water surface.
Check Start in Gear Protection
WARNING
Make certain starter will not operate when
the outboard is in gear. The start-in-gear
prevention feature is required by the
United States Coast Guard to help prevent
injuries.
Refer to the ICON User's Guide or outboard's
operator's guide for start procedure and remote
control operation.
Start the outboard and shift into FORWARD
gear.
Turn outboard OFF while remote control is in
FORWARD.
Try to restart the outboard. Outboard should not
start.
Shift into NEUTRAL and restart outboard.
Shift into REVERSE gear. Turn outboard OFF
while remote control is in REVERSE.
Try to restart the outboard. Outboard should not
start.
Emergency Stop Test
Main Station
Check emergency stop function. Push clip of
emergency stop lanyard onto master power
switch/key switch.
IMPORTANT: If boat is equipped with an op-
tional second or remote station an emergency
stop lanyard must be installed on the emergency
stop switch of the second station. Engine(s) will
not start without emergency stop clip in place.
Refer to Second or Remote Station.
Start the outboard(s). Refer to ICON User's
Guide.
RUN
OFF
1. Clip of emergency stop lanyard
1
1. Clip of emergency stop lanyard
With outboard(s) running, remove emergency
stop lanyard. Outboard(s) must STOP. If
outboard does not stop, check master power/key
switch and wiring. Repair as needed.
Reinstall clip on master power/key switch.