Switching On And Use Of Tv 401/301 Nsf - Agilent Technologies TV 401/301 NSF Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
16
15BInstructions for Use
142BUse

Switching on and Use of TV 401/301 NSF

To switch on the TV 401/301 NSF it is necessary to supply the mains.
The integrated controller automatically recognizes the interlock and
start signals presence and start up the pump.
The first pump start up is in "Soft Start" mode. When the start up
cycle is finished, the "Soft Start" mode automatically is disabled, and
the following start ups are without the "Soft Start" mode. To re-
enable the "Soft Start" mode it must be activated by the suitable
software command (see the paragraph "RS 232/485 COMMUNI-
CATION DESCRIPTION" in the appendix "Technical Information").
The green LED located on the TV 401/301 NSF base front panel
indicates with its flashing frequency the system operating conditions:
232/290
with no flashing: the pump is normally rotating;
slowly flashing (period of about 400 ms): the system is in ramp,
or in braking, or in Stop, or in "Waiting for interlock" status;
fast flashing (period of about 200 ms): error condition.
TV 401/301 NSF User Manual / 87-900-963-01 (E)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

969-8928

Table des Matières