Parameters menu

PARAMETER
PARAMETER
VALUE
Enable RS485 serial communication (MASTER-SLAVE)
Enabling serial communication permits the synchronised control of two opposing automation systems. Example: a
command signal received by MASTER automation system also opens the SLAVE automation system.
Disabled.
SLAVE automation system.
MASTER automation system. When the MASTER automation is enabled, the message
C485
Barrier model and the length of the boom selection
WARNING! An incorrect setting may cause severe damage or injury.
Use the standard parameter values indicated in the table in relation to the boom length selected.
AG/004
KB/004
boom up to 3 m
BI/004HP
AG/004
KB/004
boom from 3 m to 4.5 m
BI/004HP
AG/006
KB/006
boom from 4.5 m to 6 m
BI/006
BI/004
boom up to 3 m
BI/004
boom from 3 m or 4 m
BI/008
boom up to 8 m
Automatic closing after time pause (from barrier completely open position).
N.B.: This parameter is not visible for the SLAVE barrier, and if the value of parameter
Disabled.
From 1 a 15 automatic closure attempts after activation of photocells.
Once the number of attempts set is reached, the barrier remains open.
The barrier tries to close indefinitely.
Automatic closing after mains power outage
N.B.: This parameter is not visible for the SLAVE barrier.
Disabled. The barrier does NOT close automatically when mains power is restored.
Enabled. If the barrier is NOT completely open, when mains power is restored, the barrier closes after a 5
second pre-manoeuvre warning signalled with the flashing light (independently of the value set with param-
eter
).
illuminates on the display for a few seconds. If the SLAVE automation system is
detected correctly, C485 illuminates.