Télécharger Imprimer la page

Command And Safety Device Status Display Mode; Test Mode; Standby Mode - Roger Technology CTRL Instructions

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 124
10.2

Command and safety device status display mode

COMMAND STATUS
SAFETY DEVICE STATUS
AP
PED
PP
CH
ORO
POWER
C485
an indicator is off, the relative device is in alarm state or is not connected. The an indicator is flashing, the relative device has
been disabled with a specific parameter.
10.3

TEST mode

The TEST mode is used to test activation of the commands and safety devices with visual confirmation.
To activate the mode, press the TEST button with the automatic barrier system at rest. If the barrier is moving, pressing TEST
stops the barrier. Pressing the button again enables TEST mode.
The flashing light and the barrier open indicator lamp illuminate for one second.
N.B.: For installations with two opposing barriers, if the TEST button is pressed for the SLAVE barrier, the MASTER barrier
continues to function normally.
The status of the safety devices/inputs is shown on the right hand side of the display. The number of the terminal relative to
the safety device in alarm state flashes.
Example: STOP contact in alarm state.
N.B.: If one or more contacts are open, the barrier will neither open nor close.
If more than one safety device is in alarm state, once the problem relative to the first device is resolved, the alarm for the next
device is displayed. Any further alarm states are also displayed with the same logic.
Press the TEST button again to exit test mode.
After 10 seconds with no user input, the display returns to command and safety device state display mode.
10.4

Standby mode

POWER
COMMAND STATUS:
The command status indicators on the display (segments AP = open,
FT
PP = step mode, CH = close, PED = partial opening, ORO=clock) are
normally off. They illuminate when a command is received (e.g.: when a
COS
BREAK
step mode command is received, the segment PP illuminates).
SAFETY DEVICE STATUS:
The safety device status indicators on the display (segments FT  =
photocells, COS = sensing edge, BREAK= BreakAway system ACS/
STOP/RELEASE
BA/60 magnetic sensor or STOP/RELEASE position) are normally on. If
The command signal status is shown on the left hand side of the display for
5 seconds, ONLY when the respective command signal is active (AP, CH, PP,
PE, OR).
For example, if the open command is activated, the letters AP appear on
the display.
(rS)
This mode is activated after 30 minutes with no user input. The POWER LED
flashes slowly.
Press UP
, DOWN
No safety device in alarm state or barrier waiting for command.
STOP contact (N.C.) open.
Jumper the STOP contact.
Release handle or lock open.
Barrier inspection hatch open.
Sensing edge contact COS (N.C.) is open. Check connection. If
sensing edge is not installed, disable with
Photocell contact FT (N.C.) is open (message shown on MASTER
controller displayed). Check connection. If photocell is not installed,
disable with
.
Shatter-proof system enabled, or not connected or incorrectly con-
nected.
STOP contact active for MASTER barrier (message shown on
SLAVE controller displayed).
, + or - to reactivate the control unit.
.
69

Publicité

loading