Step mode control function selection (PP)
Open-stop-close-stop-open-stop-close...
Condominium function: the barrier opens and closes after the set automatic closing time.
The automatic closing timer restarts if a new step mode command is received with the boom in the com-
pletely open position. Step mode commands are ignored while the barrier is opening. This allows the boom to
open completely and prevents unintentional closing.
If automatic closing is disabled (
noeuvre
Condominium function: the barrier opens and closes after the set automatic closing time.
The automatic closing timer does NOT restart if a new step mode command is received.
Step mode commands are ignored while the barrier is opening. This allows the boom to open completely and
prevents unintentional closing.
If automatic closing is disabled (
noeuvre
Open-close-open-close.
Open-close-stop-open.
Pre-manoeuvre flashing warning
Disabled. The flashing light is activated during opening and closing manoeuvres.
Flashing warning signal for 1 to 10 seconds prior to every manoeuvre.
5 second flashing warning signal prior to closing manoeuvre.
Condominium function for partial open command (PED)
Disabled. The barrier opens partially in step mode: open-stop-close-stop-open...
Enabled. Partial open commands (PED) are ignored during barrier opening.
Enable "operator present" function.
N.B.: this parameter is not visible if the value of parameter
Disabled.
Enabled. The open (AP) or close (CH) button must be pressed continuously to operate the barrier. The boom
stops when the button is released.
Barrier open/photocell test function and battery saving mode indicator lamp
N.B.: This parameter is not visible for the SLAVE barrier, (which has a non-modifiable setting of
parameter
The indicator is off when the barrier is closed, and steadily lit during manoeuvres and when the barrier is open.
The indicator flashes slowly during opening manoeuvres, and is lit steadily when the barrier is completely
open. Flashing rapidly during closing manoeuvres.
If the barrier is stopped in an intermediate position, the lamp extinguishes twice every 15 s.
Set to
if the output SC is used for the photocell test. See fig. 5.
Set to
if the output SC is used for the "battery saving" function. See fig. 6.
When the barrier is completely open or closed, the controller unit deactivates any accessories connected to
terminal SC to reduce battery consumption.
N.B.: setting not available for installations with two opposing barriers. This value is not visible if the value of
parameter
Set to
if the output SC is used for the "battery saving" function and photocell test function. See fig. 6.
N.B.: setting not available for installations with two opposing barriers. This value is not visible if the value of
parameter
Enable the B73/EXP signal device to indicate barrier completely open/closed
positions (NC potential free contact)
Disabled.
Enabled.
When the boom is completely open, contact TO (NC) opens and the green LED illuminates on the B73/EXP board.
When the boom is completely closed, contact TC (NC) opens and the red LED illuminates on the B73/EXP board.
76