8

Function buttons and display

UP
DOWN
PROG
• Press the UP
and/or DOWN
• Use the + and - buttons to modify the value of the parameter. The value starts to flash.
• Press and hold the + or - button to scroll quickly through values, to modify the parameter more quickly.
• To save the new value, wait a few seconds or move onto another parameter with the UP
flashes rapidly to indicate that the new value has been saved.
• Parameters can only be modified while the motor is not running. Parameters can be viewed at any time.
9

Switching on or commissioning

Power the control unit.
The firmware version of the control unit is displayed briefly.
Version installed r3.50.
Immediately afterwards, the displays enters the commands and safety device status mode. See chapter 10.
Now set up the installation by configuring the parameters as needed.
For installations with two opposing barriers, settings must be made from the MASTER controller. Only the parameters
may be modified from the SLAVE controller.
10

Display function modes

10.1

Parameter display mode

PARAMETER
PARAMETER
See chapter 12 for detailed descriptions of parameters.
68
TEST
buttons to view the parameter you intend to modify.
VALUE
BUTTON
DESCRIPTION
Next parameter
UP
Previous parameter
DOWN
+
Increase value of parameter by 1
-
Decrease value of parameter by 1
PROG
Travel acquisition
TEST
Activate TEST mode
or DOWN