Acquisition Procedure - Roger Technology CTRL Instructions

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 124
TEST
CLOSED
1 click
11.2

Acquisition procedure:

2x360°
PROG
AP P-
x4 s
AU to
OPENING
• Press and hold PROG for 4 seconds.
• Unlock the barrier.
AGILIK-KB-BIONIK4HP-BIONIK6-BIONIK8. Turn the key anticlockwise by two full turns.
BIONIK4. Open the release cover.
• The barrier goes to 45° degree.
• After a few seconds, the message
operating parameters of the motor are determined during calibration.
• If the motor calibration procedure is successful, the message
• To lock the barrier again
AGILIK-KB-BIONIK4HP-BIONIK6-BIONIK8. Turn the key clockwise by two full turns.
BIONIK4. Close the release cover and turn the key.
• The acquisition procedure now starts. The message
speed.
• Once the barrier open mechanical stop is reached, the barrier stops briefly. The message
• The barrier closes until it reaches the barrier closed mechanical stop.
If the acquisition procedure is completed successfully, the display enters the command and safety device state display mode.
If the following error messages are shown on the display, repeat the acquisition procedure:
: calibration procedure failed.
. : acquisition error.
For more information, see chapter 16 "Alarms and faults".
72
No
No
Yes
UNLOCK
45°
AU to
OPEN
is shown on the display.
is shown on the display. The controller unit launches a calibration procedure. The
TEST
See chapters 15 and 16
1 click
Until ...
PROG
TEST
1 click
Press and hold...
TEST
ACQUISITION
PROCEDURE
Ch. 11.2
1 click
PH A5
CLOSING
CLOSED
flashes on the display.
is shown on the display and the barrier starts opening at low
ACQUISITION
PROCEDURE
Ch. 11.2
LOCK
2x360°
PH A5
flashes on the display.
Yes