Minimum Clearance To Combustible Enclosures - Napoleon Park Avenue GD82NT-PAE Manuel D'installation Et D'opération

Masquer les pouces Voir aussi pour Park Avenue GD82NT-PAE:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.2

minimum clearance to combustible enclosures

WARNING
!
Risk of fire!
The front of the appliance must be finished with any non-combustible materials such as brick, marble,
granite, etc. as long as the finishing materials does not go below the specified dimension as illustrated. As an
alternative, you can finish the appliance with drywall. See diagram below for details.
Facing and/or finishing material must never overhang into the appliance opening.
The appliance requires a minimum enclosure height measured from the appliance base.
IMPORTANT: The GD82 requires a minimum inside enclosure height of 72" (1829mm), measured from
the bottom of the appliance. For temperature requirements, this area must be left unobstructed.
26"
660mm
12 1/4"
311mm
72"
10 1/8"
1829mm
257mm
* See "VENTING" section.
COMBUSTIBLE NON-COMBUSTIBLE
COMBUSTIBLE
2"
51mm
8"
203mm
INSULATION
SLEEVE
NON-COMBUSTIBLE
1"
25mm
BRICK
0" IF NON-
2"
COMBUSTIBLE
51mm
FINISHING IS
USED SUCH AS
BRICK AND STONE.
2"
51mm
56"
1422mm
MINIMUM
PLUS RISE*
W415-2358 / B / 05.17.22