General Information; Rates And Efficiencies - Napoleon Park Avenue GD82NT-PAE Manuel D'installation Et D'opération

Masquer les pouces Voir aussi pour Park Avenue GD82NT-PAE:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Customer:
Address:
Date of Installation:
Location of Appliance:
Installer:
Dealer/Distributor contact number: ________________________________________________________________________
Serial #:
Model:
Natural Gas:
GD82NT-PAE

1.0 general information

When the appliance is installed at elevations above 4,500ft (1371m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m).
This appliance is certified to be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used. No external electricity (110 volts or 24 volts) is required for the
gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Change in flame appearance from "HI" to "LO" is more evident in natural gas than in propane.
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appli-
ance and must be installed.
The protective wrap on plated parts is best removed when the assembly is at room temperature but
this can be improved if the assembly is warmed, using a hair dryer or similar heat source.
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1

rates and efficiencies

Altitude (FT)
Max. Input (BTU/HR)
Les piles doivent être mises au rebut conformément aux lois et à la réglementation locales.
Max. Output Steady State (BTU/HR)
Certaines piles peuvent être recyclées et acceptées dans votre centre de recyclage local. Rensei-
Min. Inlet Gas Supply Pressure
gnez-vous auprès de votre municipalité au sujet des directives de recyclage.
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
Las baterías deben desecharse de acuerdo con las leyes y regulaciones locales. Algunas baterías
pueden reciclarse, y es posible que su centro de reciclado local las acepte para desecharlas.
Consulte en su municipalidad sobre las instrucciones para el reciclado.
Installer, please fill out the following information:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Propane:
4.5" Water Column (11mb)
7" Water Column (17mb)
3.5" Water Column (9mb)
standard checklist
GD82PT-PAE
NG
0 - 4,500
26,000
16,000
11" Water Column (27mb)
13" Water Column (32mb)
10" Water Column (25mb)
EN
P
5
W415-2358 / B / 05.17.22

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Park avenue gd82pt-pae