10.0 adjustments

EN
10.1

restricting vertical vents

Vertical installations may display a very active fl ame. If this appearance is not desirable, the vent exit must be
restricted using a restrictor vent kit. Refer to the "replacement parts" section of the owner's manual for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing down the fl ame pattern and creating a
more traditional gentle fl ame appearance. Specifi c instructions are included with the kit.
10.2

pilot burner adjustment

Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow.
Check Pressure Readings:
Inlet pressure can be checked by turning screw (A) counter-
clockwise 2 or 3 turns and then placing pressure gauge tubing
over the test point. Gauge should read as described on the chart
below. Check pressure with main burner operating on "HI".
Outlet pressure can be checked the same as above using screw
(B). Gauge should read as described on the chart below. Check
pressure with main burner operating on "HI".
After taking pressure readings, be sure to turn screws
clockwise fi rmly to reseal. Do not overtorque.
Leak test with a soap and water solution.
Prior to pilot adjustment, ensure that the pilot assembly has not been painted. If overspray or painting of
the pilot assembly has occurred remove the paint from the pilot assembly, or replace. Fine emery cloth or a
synthetic scrub pad (such as Scotch-Brite™) can be used to remove the paint from the pilot hood, electrode
and fl ame sensor.
Pressure
Inlet
(minimum 4.5")
Outlet
44
W415-2358 / B / 05.17.22
Natural Gas
Natural Gas
(inches)
(millibars)
*7"
17.4mb
(minimum 11.2mb)
3.5"
8.7mb
A
A
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple
SIT ELECTRONIC IGNITION
(9.5mm - 12.7mm)
Flame must envelop
INSERT PILOT ASSEMBLY
3/8" to 1/2"
(12.7mm - 9.5mm) of
Flame sensor
SIT MILLIVOLT
(9.5mm - 12.7mm)
Propane
Flame must envelop
upper
(inches)
3/8" to 1/2"
(12.7mm - 9.5mm) of
13"
thermocouple &
(minimum 11")
thermopile
10"
*Maximum inlet pressure not to exceed 13"
PSE LONG SENSOR
B
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
PILOT SCREW
thermocouple
B
VIS DU PILOTE
16.6A
3/8" - 1/2"
upper
3/8" - 1/2"
Propane
(millibars)
32.4mb
(minimum 27.4mb)
24.9mb
25.1
La fl
la th
La fl
la th