maintenance
EN
11.3

blower replacement

WARNING
!
Be careful not to tear the burner train gasket. A replacement gasket can be ordered from your local authorized
dealer.
Your appliance comes equipped with a heat circulating blower. The blower is
pre-wired and is controlled by the remote control supplied with the appliance.
Drywall dust will penetrate into the blower bearings, causing irreparable damage.
Care must be taken to prevent drywall dust from coming into contact with the
blower or its compartment. Any damage resulting from this condition is not
covered by the warranty policy.
Turn off the power to the appliance.
A.
Turn off the gas valve.
B.
Remove the glass door, logs, rear log supports, brick panels, air
C.
deflector, burner assembly, panel support, panel support bracket.
The blower mounting plate can now be removed. Remove the four
D.
screws that secure the plate to the firebox base.
The blower is secured to the firebox. Disconnect the wire connectors
E.
before attempting to remove the blower from the firebox.
Remove the two screws securing the blower and lift through blower
F.
access opening.
note:
When re-installing the replacement blower, it will be
necessary to replace the gasket (W290-0104) on the
blower mounting plate.
11.4
night light™ replacement
This appliance comes equipped with our "Night Light".
If in the event the lamp or lens needs to be replaced, follow these instructions.
Disconnect the two wire leads at the wire nut. Remove the four screws
securing the accent light assembly from the relief door. Disassemble the
light and the lamp now can be accessed.
note:
Do not handle the lamp (bulb) with bare fingers. Pro-
tect them with a clean, dry cloth.
The lamp will pull straight out of the socket. Replace with Wolf Steel
parts only, as lamp and lens are special "high temperature" products.
When re-installing, ensure integrity of gasket seal.
THE FIREBOX MUST BE SEALED.
When re-assembling the light assembly, care must
be taken with all gaskets.
"Light Leakage" from above the cast doors may
be noticed. The holes in the lamp housing are
necessary for ventilation and must not be covered.
48
W415-2358 / B / 05.17.22
BLOWER
MOUNTING PLATE
BURNER
BASE
RAIL
REMOVE 4 SCREWS
REMOVE 2 SCREWS
WIRE NUT
SHEILD
COVER PLATE
GASKET
GLASS LENS
GASKET
RELIEF
DOOR