Minimum Clearance To Combustible Enclosures - Napoleon BHD4N Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

28
5.2

MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES

EN
THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., AS LONG AS THESE MATERIALS NEVER OVERHANG
IMPORTANT: The BHD4 requires a minimum inside enclosure height of 50" (1270mm), measured from the
bottom of the appliance. For temperature requirements, this area must be left unobstructed.
11 1/2"
[292mm]
50"
[1270mm]
MINIMUM
ENCLOSURE
6" [152mm]
MINIMUM WALL
SEE THRU ONLY
* Within the appliance enclosure a minimum 3" (76mm) clearance between the top of the vent pipe and
combustible materials is required. All other clearances within the enclosure, including where the vent pipe exits
the enclosure are subject to 2" (51mm)to the sides and bottom and 3" (76mm) to the top for horizontal and 2"
(51mm) for vertical.
** See venting section.
NOTE: THIS APPLIANCE IS NOT LOAD BEARING.
IMPORTANT: The fi restop assembly provided must be used when the vent pipes pass through any
walls or are terminated horizontally.
W415-1285 / 04.14.14
INTO THE APPLIANCE OPENING.
38 1/2"
[978mm]
WARNING
!
46" [1168mm]
COMBUSTIBLE
NON-COMBUSTIBLE
BRICK
3" [76mm]
FIRESTOP
2"
[51mm]
43"
[1092mm]
MINIMUM
RISE

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Bhd4p

Table des Matières