MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES
THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., AS LONG AS THESE MATERIALS NEVER OVERHANG
IMPORTANT: The HD4 requires a minimum inside enclosure height of 46" (1168.4mm), measured from the
bottom of the appliance. For temperature requirements, this area must be left unobstructed.
COMBUSTIBLE
15 3/4"
46" (1168.4mm)
(400.1mm)
MINIMUM
MINIMUM
ENCLOSURE
HEIGHT
TOP OF
APPLIANCE
OPENING
30 1/4"
(768.4mm)
MINIMUM
* Within the appliance enclosure a minimum 3" (76.2mm) clearance between the top of the vent pipe and
combustible materials is required. All other clearances within the enclosure, including where the vent pipe exits
the enclosure are subject to 2" (50.8mm)to the sides and bottom and 3" (76.2mm) to the top for horizontal and
1" (25.4mm) for vertical.
** See venting section.
NOTE: THIS APPLIANCE IS NOT LOAD BEARING.
IMPORTANT: The fi restop assembly provided must be used when the vent pipes pass through any
walls or are terminated horizontally.
!
INTO THE APPLIANCE OPENING.
TOP OF
ENCLOSURE
CEMENT
BOARD
VENT HEAT SHIELD
2" (50.8mm)
WARNING
NON-COMBUSTIBLE
COMBUSTIBLE
3"(76.2mm)
MIN
FIRESTOP
27
3"
(76.2mm)
0" (0mm) IF
NON-COMBUSTIBLE
FINISHING IS USED,
SUCH AS BRICK
2"
AND STONE
(50.8mm)
39" (990.6mm)
MINIMUM
PLUS RISE**