14.0 troubleshooting

EN
WARNING
!
Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or
removed.
Turn off gas and electrical power before servicing the appliance.
Appliance may be hot. Do not service until appliance has cooled.
PSE THERMOCOUPLE
Do not use abrasive cleaners
3/8" - 1/2"
(9.5mm - 12.7mm)
symptom
Flame must envelop
Main burner fl ame is a
upper
blue, lazy, transparent
3/8" to 1/2"
fl ame.
(12.7mm - 9.5mm) of
(This is not applicable
thermocouple
in outdoor appliances)
Flames are consistently
too large or too small.
SIT ELECTRONIC IGNITION
Carboning occurs.
3/8" - 1/2"
INSERT
(9.5mm - 12.7mm)
PHOTO
Flame must envelop
upper
OF VALVE
3/8" to 1/2"
(12.7mm - 9.5mm) of
Flame sensor
SIT MILLIVOLT
3/8" - 1/2"
(9.5mm - 12.7mm)
Carbon is being
deposited on glass,
logs, rocks, media, or
Flame must envelop
combustion chamber
upper
surfaces.
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple &
thermopile
White / grey fi lm forms.
PSE LONG SENSOR
Exhaust fumes smelled
in room, headaches.
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
symptom
(12.7mm - 9.5mm) of
thermocouple
Pilot will not light. Makes
noise with no spark at
pilot burner.
56
W415-2358 / B / 05.17.22
problem
Blockage in vent.
Incorrect installation.
Appliance is over-fi red or under-
fi red.
Pressure
HERE
Inlet
Outlet
Air shutter improperly adjusted.
Air shutter is blocked.
Flame is impinging on the glass,
logs, rocks, media or combus-
tion chamber.
Sulphur from fuel is being depos-
ited on glass, logs, or combus-
tion chamber surfaces.
Appliance is spilling.
(This is not applicable in outdoor
appliances).
problem
Wiring: short, loose, or damaged
connections
(poor fl ame rectifi cation).
No signal from remote with no
pilot ignition.
3/8" - 1/2"
(9.5mm - 12.7mm)
test solution
La flamme doit envelopper
-
Remove blockage. In really cold conditions, ice buildup may occur
la thermocouple de 3/8" à
on the terminal and should be removed as required. (To minimize this
1/2"
from reoccuring, the vent lengths that pass through unheated spaces
(attics, garages, crawl spaces) should be wrapped with an insulated
(9.5mm - 12.7mm)
mylar sleeve).
-
Refer to "venting" section to ensure correct installation.
-
Check pressure readings:
Inlet pressure can be checked by turning screw (A) counter-clock-
wise 2 or 3 turns and then placing pressure gauge tubing over the
test point. Gauge should read as described on the chart below.
Check that main burner is operating on 'HI'. Outlet pressure can be
checked the same as above using screw (B). Gauge should read as
3/8" - 1/2"
described on the chart below. Check that main burner is operating
(9.5mm - 12.7mm)
on 'HI'. After taking pressure readings, be sure to turn screws
clockwise fi rmly to reseal. DO NOT OVER TORQUE.
Leak test with a soap and water solution.
La flamme doit envelopper
Natural Gas
Natural Gas
la sonde de flamme de
(inches)
(millibars)
3/8" à 1/2"
(9.5mm - 12.7mm)
*7"
17.4mb
(minimum 4.5")
(minimum 11.2mb)
3.5"
8.7mb
*Maximum inlet pressure not to exceed 13" w.c.
-
Return air shutter to specifi ed opening, see "venturi adjustments"
section in the installation manual.
3/8" - 1/2"
-
(9.5mm - 12.7mm)
Ensure air shutter opening is free of lint or other obstructions.
-
Ensure the media is positioned correctly in the appliance.
La flamme doit
-
Open air shutter to increase the primary air.
-
Check the input rate: check the manifold pressure and orifi ce size as
envelopper la
specifi ed by the rating plate.
thermocouple et
-
Ensure door gaskets are not broken or missing and the seal is tight.
thermopile
-
Ensure vent liners are free of holes and well sealed at all joints.
de 3/8" à 1/2"
-
Check that minimum rise per foot (meters) has been adhered to for
(9.5mm - 12.7mm)
any horizontal venting.
-
Clean the glass with a recommended gas fi replace glass cleaner. DO
NOT CLEAN GLASS WHEN HOT.
-
If deposits are not cleaned off regularly, the glass may become
permanently marked.
-
Check door seal.
-
Check for exhaust damage.
-
Check that venting is installed correctly.
3/8" - 1/2"
-
Room is in negative pressure; increase fresh air supply.
(9.5mm - 12.7mm)
La flamme doit envelopper
la thermocouple de 3/8" à
1/2"
test solution
(9.5mm - 12.7mm)
-
Verify the thermocouple/sensor is clean and the wiring is undamaged.
-
Verify the interrupter block is not damaged or too tight. Verify
connections from pilot assembly are tight; also verify the connections
are not grounding out to any metal. (Remember, the fl ame carries the
rectifi cation current, not the gas. If fl ame lifts from pilot hood, the circuit
is broken. A wrong orifi ce or too high of an inlet pressure can cause the
pilot fl ame to lift)*. The sensor rod may need cleaning.
-
Reprogram receiver code.
-
Replace receiver.
Propane
Propane
(inches)
(millibars)
13"
32.4mb
(minimum 11")
(minimum 27.4mb)
10"
24.9mb