ADD FASTENER TYPE
REAR VENT
3.5
appliance vent connection
A. Install the inner fl ex pipe to the appliance. Secure with a minimum of
#8 X 1/2"
Self
three screws when installing 3"/5", 4"/7" or 5"/8" venting, or six screws
Drilling
when installing 8"/10" or 8"/11" venting. Seal the joint and screw holes
Mill Pac
Screws
Sealant
using Mill Pac sealant (W573-0007) (not supplied).
B. Install the outer fl ex pipe to the appliance. Secure with a minimum of
three screws when installing 3"/5", 4"/7" or 5"/"8 venting, or six screws
1 1/2"
when installing 8"/10" or 8"/11" venting. Seal the joints using high
(38.1mm)
Overlap
temperature red RTV silicone (W573-0002) (not supplied).
3.6
horizontal air terminal installation
A.
Move the appliance into position. Measure
the vent length required between terminal and
appliance taking into account the additional
length needed for the fi nished wall surface and
any 2" (50.8mm) overlaps between venting
components.
Apply a heavy bead of Mill Pac sealant
B.
(W573-0007) (not supplied) to the outer edge of
the inner collar of the appliance. Attach the fi rst
inner rigid pipe component and secure using a
minimum of three screws. Repeat using the outer
rigid pipe. Seal using Red RTV Silicone (W573-0002)
(not supplied).
C.
Insert the vent pipes through the fi restop maintaining the required clearance to
combustibles. Apply a heavy bead of Red RTV Silicone (W573-0002) (not supplied) to both the
inner sleeve and outer sleeve of the air terminal. Slide the terminal sleeves into the rigid pipes a minimum
of 1 1/4". Holding the air terminal (lettering in an upright, readable position), secure to the exterior wall and
make weather tight by sealing with caulking (not supplied).
The air terminal mounting plate may be recessed into the exterior wall or siding no greater than the
depth of the return fl ange.
3.7
extended horizontal air terminal installation
FOR REAR VENT ONLY: A 45° corner installation can have 0" (0mm)
rise between the appliance combustion air collar and the air terminal.
In this case, vent lengths must be kept to a maximum of 24" (61cm).
For longer vent lengths, a minimum vertical rise of 24" (61cm) is required.
A.
Follow the instructions for "horizontal air terminal installation" section.
B.
Continue adding components alternating inner rigid pipe and outer
rigid pipe. Ensure that all inner rigid pipe and elbows have sufficient
vent spacers attached and each component is sealed and securely
fastened to the one prior. Attach the inner telescopic sleeve to the
vent run. Repeat using the outer telescopic sleeve. Seal and secure
as before. To facilitate completion, attach inner and outer couplers
to the air terminal.
C.
Install the air terminal. See "horizontal air terminal installation" section.
Extend the outer telescopic sleeve; connect to the air terminal assembly.
Fasten with self tapping screws and seal.
TOP VENT - FLEX
#8 X 1/2"
Self Drilling
Screws
1 1/4" (31.8mm)
Overlap
Mill-Pac Sealant
Red RTV
Silicone
#10x2"
SCREWS
installation
TOP VENT - RIGID/FLEX
INSERT
#8 X 1/2"
Self Drilling
IMAGE HERE
Screws
Mill-Pac
Sealant
19.1
CAULKING
INNER
RIGID
OUTER
PIPE
RIGID
PIPE
2" (50.8mm) OVERLAP
HI-TEMP
SEALANT
18.3A
TOP VENT
Air terminal
Telescopic sleeve
Add Image
20" (51cm)
Coupler
Venting
REAR VENT
Air terminal
Telescopic sleeve
20" (51cm)
Coupler
Venting
32.1A