AKD Safety Guide | 1   English

1.4.3 Technical Data AKD-xzzz06

Electrical Data
Rated supply voltage (L1/L2/L3)
Rated supply input frequency
Rated input power for S1 oper-
ation @ 240V
Rated input current
at 1x120 V
at 1x240 V
at 3x120 V
at 3x240 V
Permitted switch on/off fre-
quency, mains
Max. inrush current
Rated DC bus link voltage
(Bus Turn on Delay 3ph 1 s)
Regen circuit
max. continuous power
external regen resistor
Continuous output current ( ± 3%), single-phase or three-phase
at 120 V
at 240 V
Peak output current (for 5 s, ± 3%) Arms
Continuous output power @ rated input current
at 1x120 V
at 1x240 V
at 3x120 V
at 3x240 V
Peak output power (for 1 s)
at 1x120 V
at 1x240 V
at 3x120 V
at 3x240 V
Noise emission (low speed/high
speed fan)
Mechanical data
Weight (standard width)
Weight (extended width*)
Dimensions
*= extended width: AKD drives with integrated IC, MC or M1 option card.
More technical data see Installation Manual.
14
Kollmorgen | kdn.kollmorgen.com | December 2015
Units
AKD-
AKD-
x00306
x00606
V
3 x 120 V to 240 V ±10%
1 x 120 V to 240 V ±10%
Hz
50 Hz to 400 Hz ±5% or DC
kVA
1.2
2.38
A
5.0
9.9
A
5.0
9.9
A
2.3
4.6
A
2.3
4.6
1/h
A
10
10
V
kW
0.77
1.5
Ohm
33
33
Arms
3
6
Arms
3
6
9
18
VA
312.5
625
VA
625
1250
VA
312.5
625
VA
625
1250
kVA
0.937
1.875
kVA
1.875
3.750
kVA
0.937
1.875
kVA
1.875
3.750
dB(A)
-
33/39
kg
1.1
1.1
kg
1.3
1.3
mm
see (➜ # 175)
AKD-
AKD-
x01206
x02406
3x240 V
±10%
3.82
7.6
12
-
12
-
9.2
-
9.2
18.3
30
10
20
170 to 340
3
6
15
8
12
-
12
24
30
48
1250
-
2500
-
1250
-
2500
5000
3.125
-
6.250
-
3.125
-
6.250
10
37/43
41/56
2
3.7
2.2
4