AKD Safety Guide | 8 Appendix
8.2.2.5 Connector assignment AKD-M02406, AKD-M00307 to -M02407
Connector
24V/STO X1
Motor X2
Regen X3
Power X4
Motion Bus X5, X6
Control signals X7/X8
Encoder Emulation X9
Feedback X10
Service Port X32
CAN In/Out X12/13
Control signals X35/X36
1
single-line connection
2
single-line connection with recommended conductor cross section
3
rated voltage with pollution level 2 (lowest values allowed by UL840 and IEC60664)
188
Kollmorgen | kdn.kollmorgen.com | December 2015
Type
Terminal Connector, 3 poles
Terminal Connector, 6 poles
Terminal Connector, 4 poles
Terminal Connector, 4 poles
RJ45
Terminal Connector, 10 poles 1.5 mm², 16 awg
SubD 9pin (male)
SubD 15pin HD (female)
RJ45
RJ25
Terminal Connector, 8 poles
1
Max. Cross Section
1.5 mm², 16 awg
10 mm², 8 awg
10 mm², 8 awg
10 mm², 8 awg
0,5 mm², 21 awg
0,5 mm², 21 awg
0,5 mm², 21 awg
0,5 mm², 21 awg
0,5 mm², 21 awg
1.5 mm², 16 awg
2
3
Current
Voltage
8 A
160 V
30 A
1000 V
30 A
1000 V
30 A
1000 V
1 A
<100 V
10 A
250 V
1 A
<100 V
1 A
<100 V
1 A
<100 V
1 A
<100 V
10 A
250 V