INSTALLATION
8.1
Safety instructions
DANGER!
Risk of injury from high pressure!
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
WARNING!
Risk of injury from improper installation!
▶ Installation may be carried out by authorized technicians only and
with the appropriate tools!
Risk of injury from unintentional activation of the system and
an uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.
For control function I – Danger if pilot pressure fails!
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.
▶ To ensure a controlled restart, first pressurize the device with pilot
pressure, then switch on the medium.
Risk of injury from moving parts in the device!
▶ Do not reach into openings.
Type 2012
Installation
8.2
Before installation
Installation position: any, preferably with the actuator face up.
Procedure:
→
Before connecting the valve, ensure the lines are flush.
→
Observe direction of flow.
8.2.1
Preparatory work
→
Clean pipelines (sealing material, swarf, etc.).
Devices with welded body
Remove the actuator from the valve body:
→
Clamp the valve body in a holding device.
NOTE!
Damage to the seat seal or the seat contour!
▶ When removing the actuator, ensure that the valve is in open
position.
→
Control function A:
pressurize the lower control air connection with compressed air
(6 bar): valve opens.
→
Using a suitable open-end wrench, place the wrench flat on the
tube.
→
Unscrew the actuator from the valve body.
english