Stiga Autoclip 221 Manuel D'utilisation page 44

Masquer les pouces Voir aussi pour Autoclip 221:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47
INSTALLATION OF THE CHARGING STATION PROTECTED BY A TERRACE
EN
Notes:
the example shows how to install the charging station under a terrace, by setting the robot to exit correctly from the narrow area
where it is located. This is done by setting the dimensions of the secondary areas in such a way that the percentage is equal to
100%.
References:
A. charging station under a terrace. There should be 2 m straight perimeter wire before the charging base entrance.
B. the corridor minimum width, where the charging station is located, must be 70cm.
C. in case of V-meter mode to re-enter the charging station, it is recommended to install a recall on wire before the entrance of
the narrow corridor, where the charging station is located.
D - E: work exiting in secondary area. See "Programming". Their programming is necessary to allow the robot to correctly exit
from the narrow corridor, where the charging station is located.
F. trampoline. It is recommended to delimit it with perimeter wire.
Programming:
garden total size: 1100 sm.
working time:
-
Autoclip 225 S: time 1: 09:00 - 20:00
-
Autoclip 230 S: time 1: 10:00 - 12:30 time 2: 15:30 - 17:00
secondary areas:
-
area 1- D:
-
percentage: 50%;
-
direction: counter-clockwise;
-
distance: 30m (distance between the charging station and the point "D");
-
mode: follow wire.
-
area 2- E:
-
percentage: 50%;
-
direction: clockwise;
-
distance: 30m (distance between the charging station and the point "E");
-
mode: follow wire.
User's manual
D
C
A
> 2m
> 70cm
B
42
E
0 cm
0 cm
F

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Autoclip 225 sAutoclip 230 s

Table des Matières