Fastener Placement Restriction - Napoleon Luxuria Serie Manuel D'installation

Masquer les pouces Voir aussi pour Luxuria Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12.0 fi nishing
fi nishing
EN
WARNING
!
Risk of fi re!
Never obstruct the front opening of the appliance.
The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite,
etc., provided that these materials do not go below the specifi ed dimension, as illustrated.
Do not strike, slam, or scratch. Do not operate appliance with glass removed, cracked, or scratched.
Facing and/or fi nishing material must never overhang into the appliance opening.
The glass door assembly is a safety device designed to pivot forward when relieving excess pressure that might
occur. Finishing or other materials must not be located in the opening surrounding the door as this will interfere
with the doors ability to relieve pressure.

12.1 fastener placement restriction

No fasteners permitted.
No fasteners permitted with greater than 3/4"
penetration into appliance.
When securing non-combustibles, we suggest using high temperature construction adhesive within 2" (5.08cm)
above and to the sides from the appliance opening and 8" (20.3cm) below the appliance opening. DO NOT
SCREW IN THE RESTRICTED AREA AS THIS COULD DAMAGE THE INTERNAL COMPONENTS OF THE
APPLIANCE THAT CAN CAUSE INJURY OR DEATH.
This applies to both single-sided and see-thru appliances.
Maximum screw length to be used outside the restricted screw area is 3/4" greater than fi nishing material
thickness.(i.e. no fastener permitted that penetrates the appliance more than 3/4"