Electrical Information; Hard Wiring Connection; Receptacle Wiring Diagram; In The Event Of A Power Failure - Napoleon Luxuria Serie Manuel D'installation

Masquer les pouces Voir aussi pour Luxuria Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.1

hard wiring connection

It is necessary to hard wire this appliance.
Permanently framing the appliance with an enclosure, requires the appliance junction box to be hard wired. This
appliance must be electrically connected and grounded in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70-1996 National
Electrical Code in the United States.
7.2

receptacle wiring diagram

7.3

in the event of a power failure

If the battery holder/switch is equipped with batteries, the appliance will still have ON/OFF functions during a
power failure. Refer to "operation" section in the Owner's manual when communications between battery holder/
switch and remote have been lost. The battery holder/switch will emit a "beep" sound to confi rm programming
has been successful once power is restored. During a power failure, if the fi replace was on, the fl ame height will
stay at the setting prior to the failure. If off when the failure occurs and then turned on, the fl ame height will come
on at "HI". The fl ame height can then be controlled by the remote.
In most cases, your appliance will operate with simple functions available until power is restored. All other electri-
cal features / accessories will not work during a power failure.

7.0 electrical information

L1
L2
To optional LHAD kit
venting installation
Power Supply
Cable Connector
W415-2035 / C / 04.30.21
EN