Installation Option 3 - Rear Opening - Napoleon Luxuria Serie Manuel D'installation

Masquer les pouces Voir aussi pour Luxuria Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.3

installation option 3 - Rear Opening

Suitable for Dynamic Heat Control™ Plus
Suitable for Dynamic Linear Trim
Minimum air outlet opening dimension must be followed. The opening is required to be framed no more than 1.5" below the
enclosure top (see option 3 diagram) to avoid trapping heat in the upper areas and centered on the appliance center. Framing
the rear opening lower will overheat the appliance, the enclosure, and fi nishing material.
Dynamic Heat
Control™ rear
air outlet opening
must be located
out of reach of
the user. Opening
must not be re-
stricted by furnish-
ings or decor.
Air outlet opening is required to be centered with the appliance.
WARNING
!
When using a rear (or two-sided) air out-
let opening, it is critical that the adjoin-
ing room or living spaces are in direct
air communication (i.e. of an open plan
confi guration or connected by a perma-
nently open doorway or archway). This
prevents the appliance from being in a
negative pressure more than that of the
adjoining room. Failure to follow these
requirements can result in reversing the
Dynamic Heat Control™ air fl ow and
will cause the appliance, glass guard
assembly, and fi nishing materials to
overheat, creating a fi re hazard.
note:
Increasing the air outlet opening will allow the appliance, the glass barrier, the temperatures on the surfaces above the fi replace open-
ing, and the enclosure be at cooler temperatures. It will also allow the air to circulate more effectively in the room. However, if the
appliance is equipped with the Dynamic Heat Control™ Plus, then the opening size must be 80 sq. in. for models LVX38-1
and LVX50-1, or 160 sq. in. for models LVX62-1 and LVX74-1.
(Q x R)*
S
Room 1
Access
Side of
fi replace
installation planning
AIR OUTLET
OPENING IS HOT
Room 2
WHEN APPLIANCE
IS OPERATING!
ceiling
0-1.5" Max
enclosure top
must be installed
W415-2035 / C / 04.30.21
EN
2 1/2"
Other
min
room
2-3"
6" min
Wall mounted
object (picture
frame,
appliance, etc.)
ALTERNATIVE
31

Publicité

Chapitres

Table des Matières
loading