7.0 electrical information
EN
7.1
hard wiring connection
It is necessary to hard wire this appliance.
Permanently framing the appliance with an enclosure requires the appliance junction box to be hard wired.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence
of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70-1996
National Electrical Code in the United States.
7.2
wiring diagram
WARNING
!
•
Do not wire 110 volts to the valve or wall switch.
DC BACK-UP
-
+
TRANSFORMER
+
-
DC SUPPLY
note:
This appliance comes equipped with a battery back-up. If this backup is used, install four AA batteries (not
supplied) into the holder and connect to the wire harness. Place near the IPI board. Connect the battery holder
to the wire harness before using the appliance. Place near the IPI board. (Batteries not included). If backup is
used, it must be connected to the 6 volt battery pack supplied.
32
W415-1337 / B / 09.25.18
ON / OFF
SWITCH
ON / OFF
DISCONNECT THESE
CONNECTORS TO THE
ON/OFF SWITCH AND
CONNECT TO
OPTIONAL
THERMOSTAT OR
REMOTE .
VALVE
GROUND
EYELET
GROUND
GREEN
ORANGE
VALVE
ELECTRONIC
IPI BOARD
DFC