7.0 electrical information
electrical information
EN
7.1
hard wiring connection
It is necessary to hard wire this appliance.
Permanently framing the appliance with an enclosure, requires the appliance junction box to be hard wired.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence
of local codes, use the current CSA C22.1 Canadian electrical code in Canada or the ANSI/NFPA 70-1996
National electrical code in the United States.
7.2
wiring diagram
WARNING
!
•
Do not wire 110 volts to the valve or wall switch.
This appliance comes equipped with a battery back-up. If this backup is used, install four AA batteries (not
supplied) into the holder and connect to the wire harness. The connection point resembles a 9 volt battery type of
terminal, however, a 9 bolt battery must not be connected.
28
W415-1606 / D / 08.23.18
NIGHT
BLOWER
LIGHT