4

ELECTRICAL CONNECTIONS

Complete the installation in line with low voltage regulations and applicable rules.
Use cables with sufficient section, always earthed.
Check the manufacturer's instructions for all the elements installed.

General connections

BAT
(2x12V/1,2 Ah)
CHG
ADO01
ADO01
Charger kit (CHG) + batteries (2x 12V /
1.2Ah)
BAT
Batteries
SMF
Traffic light card AEPS1-001
SCA
SCA light (24Vdc)
A.T (FT1) Total opening key device
A.P (ST2) Pedestrian opening key device
SG.C (FT1) Closing safety device (mechanical strip or
photocell)
SG.A (FT2) Opening safety device (mechanical strip
or photocell)
O
When installing batteries, ensure they are connected through an external
charger (CHG). Do not connect them directly to the control board.
The ADO01 kit is recommended, consisting of a charger and two 12V /
1.2Ah batteries, as it has been designed for use in this operator.
ST1
ST2
COM
FT1
FT2
FT
Output 24Vdc for photocells (cable
connectors 6 and 7)
AUX
Output 24Vdc (cable connectors 7 and 8)
DEST
Flashing light (max. 60W)
DOS424E: 230VAC, 50Hz
DOS424EM: 125Vac, 60Hz
LG
Garage light (max. 2,300W resistive)
DOS424E: 230VAC, 50Hz
DOS424EM: 125Vac, 60Hz
ANT
Antenna connection
R.E
Plug-in receiver