ELECTRICAL CONNECTIONS

The ARES operators, along with the recommended
switchboards, allow the implementation of a
slowdown system, with the speed slowing down at
the end of the closing and opening operations.
We recommend using the VIVO-M101(M) switchboard (for single operator installations) and
VIVO-M201(M) (for twin operator installations).
VIVO-M201(M)
P1 P2 P3
ST1
FT1
A1, A2
Operators
C1, C2
Capacitors
DL4
Gate opening
DL5:
Gate closing
PUL1
Close mini-pushbutton
PUL2
Open mini-pushbutton
T
Earth connection
Turning direction:
• When pressing PUL1 (close), DL5 lights up and the A1 G2-G3 and A2 G5-G6
cable connectors are activated.
• When pressing PUL2 (open), DL4 lights up and the A1 G1-G3 and A2 G4-G6
cable connectors are activated.
If the turning direction is not correct, interchange the cables connected in cable
connectors G1-G2 or G4-G5.
Operators of 125 or 230 Vac
FCA2 COM FCC2
SCA
P4 P5 P6
P15 P14 P16
P7 P8
P11 P12
P22 P23
G7 G8
Courtesy
24Vac
STOP
LOCK
ST2
FT2
FCA1
FCC1
Light
A2 operator connections:
G4 Open
G5 Close
G6 Common (COM), grey cable
G4
G5
G6
G1
G2
G3
G9 G10
N
L
POWER
Lamp.
MOTOR2 (G2-G1-COM)
MOTOR1 (G2-G1-COM)
G4 G5 G6
G1 G2 G3
A1 operator connections:
G1 Open
G2 Close
G3 Common (COM), grey cable
INSTALLATION
VIVO-M201: 230Vac/50Hz
VIVO-M201M: 125Vac/60Hz
P169V
ARES electro-mechanical operator
33