Electrical Connections - Erreka DINGO Manuel De L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTALLATION
4

ELECTRICAL CONNECTIONS

Complete the installation in line with low voltage regulations and applicable rules.
Use cables with sufficient section, always earthed.
Check the manufacturer's instructions for all the elements installed.
General connections
O
When installing batteries, ensure they are connected through an external charger
(CHG). Do not connect them directly to the control board.
The ADN1 kit is recommended, consisting of a charger and two 12V /1.2Ah batteries,
as it has been designed for use in this operator.
ADN1
ADN1 Charger kit (CHG) + batteries (2x12V/1.2Ah)
BAT
Batteries
SMF
Traffic light card AEPS1-001
SCA
SCA light (24 Vdc)
A.T
Total opening key device
A.P
Pedestrian opening key command
SG.C
Closing safety device (mechanical strip or
photocell)
SG.A
Opening safety device (mechanical strip or
photocell)
52
Installation Guide
FT
Output 24Vdc for photocells (cable connectors 6 and 7)
AUX Output 24Vdc (cable connectors 7 and 8)
DEST Flashing light (max. 60W)
DNS424E: 230Vac;
DNS424EM: 125Vac
LG
Garage light (max. 2300W resistive)
DNS424E: 230Vac;
DNS424EM: 125Vac
ANT Antenna connection
R.E
Plug-in receiver
P275F