Erreka DOLFIN Manuel De L'utilisateur page 65

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Radio code programming (only with RSD) and gate open/close programming (D1= "P")
O
Before programming the gate open/close,
ensure the turning direction of the operator is
correct (see "Initial Conditions Programming
(D1= "C")" on page 60).
The radio code programming described below is
only valid if the RSD plug-in receiver has been
installed. If a different receiver is used, programme
the radio code as described in the corresponding
instructions.
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
P flashing. Press ENTER to confirm. D2 flashes.
D1
D2
D3
D4
P
1
o
ç
2
o
ç
3
o
ç
Main Functions Programming (D1= "F")
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
F flashing. Press ENTER to confirm. D2 flashes.
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
D1
D2
Parameter
F
1
Functioning mode
2
Standby in automatic mode
3
Pedestrian opening
a. For further details, see "Functioning modes" on page 50.
until D1 shows the letter
V
Total opening radio code
programming
Pedestrian opening radio
code programming
Gate open/close
programming
until D1 shows the letter
V
until the required D2
V
D3
D4
0
1
a
0
2
1
5
0...5. 0...9
0
0
1
0
2
0
3
0
4
0
5
0
START UP AND PROGRAMMING
3 Press the buttons ^ and
parameter appears (see chart). Press ENTER to
confirm. D3 and D4 flash.
4.a Radio code programming (D2=1 or D2=2):
• Press the transmitter button. If the code is
correctly programmed, D3-D4 stop flashing
(remain static).
4.b Gate open/close programming (D2=3):
• Press ENTER. D3-D4 stop flashing (remaining
static)
• Press the total opening button. D3-D4 flash
again whilst the programming of the operations
is done automatically. The gate carries out the
following movements:
– Reset (close position search)
– Total opening
– Total close
• When programming is finished, D3-D4 stop
flashing (remaining static).
5 Press ESC to return to the previous display.
4 Press the buttons ^ and
D4 value appears (see chart). Press ENTER to
confirm.
5 Press ESC to return to the previous display.
For operation different to the options defined in this
menu, access the advanced functions menu (see
"Advanced Functions Programming (D1= "A")" on
page 62).
D e f a u l t
Options or values
option
Automatic
x
Step-by-step
x
15 seconds
59
= 59 sec;
x
Pedestrian opening is not carried out
10% of total opening
20% of total opening
30% of total opening
40% of total opening
50% of total opening
until the required D2
V
until the required D3 and
V
2.5
= 2 min. 50 sec., etc
DOLFIN operator for sliding gates
61

Publicité

Table des Matières
loading

Table des Matières