CAUTION: Errors that can occur during alignment and adjustment of the device, can result in malfunction of the
device. This can cause the user to fall.
COMPLETING SETUP
SOCKET/ FRAME CONTACT POINTS
Care should be taken when configuring the socket / frame and adapters so that contact only occurs at the posterior
apex of the device.
DO NOT remove the devices protective cover. This will immediately void the warranty.
ACCOMPANYING SOFTWARE
Prosthetists have the option of using RHEOLOGIC Workbench for Windows PC and Össur Logic in expert mode
for Apple iOS devices to set up and adjust parameters in the knee.
The end user can use Össur Logic in the default user mode to monitor basic knee parameters such as battery
status and step count.
For more information please refer to the instructions for use for the individual software products.
SPECIFICATIONS
STRUCTURAL SPECIF ICATION
• Net weight: 1.61 kg (3.56 lbs)
• Frame construction: Aluminum
• Knee flexion available: 120 degrees
• Clearance and dimensions (Figure 2)
SOFTWARE COMPATIBILITY
RHEOLOGIC
software version 1.2 or greater for PCs or Össur Logic software for iOS devices.
TM
PRODUCT SPECIFICATION INFORMATION
The device is tested and certified to comply with the IEC/EN60601- 1, standard of electrical safety of medical
devices and IEC/EN60601-1-2, electromagnetic compatibility for medical electrical devices and ISO 10328. The
company fulfills the requirements of ISO13485, MDD 93/42/EEC, and the device is CE marked accordingly.
ENVIRONMENTAL CONDITIONS
• Operating temperature: -10 °C to 40 °C (14 °F to 104 °F)
• Operating humidity: 0% - 100% relative humidity
• Storage temperature: 0 °C to 45 °C (32 °F to 113 °F)
• Storage humidity: 10% - 90% relative humidity (non-condensing)
CAUTION: If the unit is either used or stored in cold environment (below 0 °C) for a period of time, it can cause
reduced extension speed of the device. If the device will not regain its normal function again it must be sent in
for service to Össur.
WARNING: The device is not designed for use in presence of flammable gases or oxygen rich environments.
POWER SUPPLY INFORMATION
• The power supply provided with the unit is certified to comply with medical electrical equipment standards. It is
only safe to use Össur recommended power supplies.
• Input: 100–240 VAC
• Input frequency: 50–60 HZ
• Input current: 0.6A
• Output voltage: 24 VDC
• Output current: 1.0 A
• Operating temperature: 0 °C to 40 °C (32°F to 104°F)