6
Function modules (optional)
Danger!
•
The pins of the FIF interface have a basic isolation (single-insulating distance).
•
Protection against contact in the event of a defective insulating distance can only be ensured
by external measures (e.g. double insulation).
Which function modules can be used?
8200 vector with a function module
8200 vector with two function modules
6.1
Mounting
Function module on interface FIF I
1. Disconnect the controller from the mains and wait for at least 3 minutes!
2. Remove and keep blind cover
3. Remove and keep the FIF protection cover
4. Plug the function module
on the interface FIF I.
5. Press against the function module until it is snapped into place.
6. Assign the terminals of the function modules (PES: HF- shield connection by
connecting the shield to PE)
L
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Function modules (optional)
Possible function modules on FIF I
Possible function modules on FIF I
Possible function modules on FIF II
.
.
Standard I/O
Standard I/O PT
Application I/O
INTERBUS
PROFIBUS-DP
LECOM-B (RS485)
System bus (CAN)
INTERBUS
PROFIBUS-DP
LECOM-B (RS485)
System bus (CAN)
Standard I/O
Standard I/O PT
Function module on interface FIF II
1. Disconnect the controller from the mains and wait for at least 3 minutes!
2. Remove and keep blind cover
.
3. Remove and keep the FIF protection cover
4. Plug the function module standard I/O
5. Press against the function module until it is snapped into place.
6. Assign the terminals of the function modules (PES: HF- shield connection by
connecting the shield to PE)
– Wiring of the terminals "controller inhibit (CINH)": 88
Mounting
E82ZAFS
E82ZAFS100
E82ZAFA
E82ZAFI
E82ZAFP
E82ZAFL
E82ZAFC
E82ZAFI
E82ZAFP
E82ZAFL
E82ZAFC
E82ZAFS
E82ZAFS100
8200vec278
.
on the interface FIF II.
87
EDK82EV903 DE/EN/FR 2.2