12
3.4
Equipment features
The InPro 5500 i is available with three different pro-
cess connections for CO
and carbonated soft drink applications.
– Varivent DN40
– TriClamp 2"
– 28 mm; M42
The InPro 5500 i can be used in applications where
CIP and SIP cycles are applied. The sensor has a
protective function where the CO
shuts off during elevated temperatures (> 55 °C) and
turns back on when it cools down (< 50 °C). This
function ensures that the TC-chip will not be dam-
aged during CIP / SIP.
Picture:
InPro 5500 i
30 035 328
2.32"
6 mm/0.24"
13.5 mm/
0.53"
28 mm
1.10"
measurement in brewery
2
59 mm
© 06 /14 Mettler-Toledo AG
InPro 5500 i CO
-measurement loop
2
5-pin connector
Sensor head
Purge gas outlet
Purge gas inlet
Process connection
28 mm shaft
Diffusor
MembraCap
Printed in Switzerland
Sensor