H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
9
Configuring the Welding Unit
With the operator identity card, the welding unit can be reconfigured.
When the MENU key is pressed, the "Enter Menu Code" message ap-
pears on the screen. After the code was read from the operator card,
the selection menu in Display 17 shows.
At "Settings," the parameters related to the welding unit itself and
its operation can be set. At "Recording," the traceability data that
have to or need not be recorded and written into the reports can be
enabled or disabled. The desired sub-menu is selected using the ñ and
ò arrow keys. Then to access that sub-menu, press the MENU key.
In both parts of the configuration menu, use the ñ and ò arrow keys
to select the desired set-up option. Use the ð arrow key to toggle
between "on" and "off" for that set-up option.
If a "M" is shown next to a set-up option, this indicates that a sub-
menu is accessible here by pressing the MENU key.
Press the START/SET key to confirm the set-up and save it to
memory.
9.1

Understanding the "Settings" Sub-menu

"Check Code Expiry on" means that the welder identification code has
to be current and not expired (default period of validity 2 years
from code issuance), or the welding operation cannot be started,
"off," that the validity of the code is not checked at all.
"Memory Control on" means that when the system memory is full of
reports, the unit will be blocked until the reports are printed or
downloaded, "off," that it works but that the oldest report will
be overwritten.
"Welder Code Options – M – " means that by pressing the MENU
key, the user can access a sub-menu that allows determining
when the welder code, if it is enabled at "Recording," has to be
entered:always, i. e. before evey single welding operation, only
before the first welding operation after switching the unit on or
only after the first welding operation of a new day/date.
"Language – M – " means that by pressing the MENU key, the user
can access a sub-menu for selecting the display and report lan-
guage (see Sect. 9.1.1).
"Date/Time – M – " means that by pressing the MENU key, the user
can access a sub-menu for setting the clock (see Sect. 9.1.2).
"Buzzer Volume – M – " means that by pressing the MENU key, the
user can access a sub-menu for setting the volume of the status
buzzer (see Sect. 9.1.3).
"Temperature Unit – M – " means that by pressing the MENU key, the
user can access a sub-menu for selecting centigrade or Fahrenheit
as the unit for the temperature.

9.1.1 Selecting the Display Language

When the "Select Language" sub-menu was selected, the screen
changes and the display reproduced in Display 12 appears.
Use the arrow keys ñ and ò to select one of the options, "Deutsch,"
"English," and "Français" and confirmby pressing the START/SET
key.

9.1.2 Setting the Clock

When the "Set Clock" sub-menu was selected, the screen changes and
the display reproduced in Display 13 appears.
Version June 2013
HÜRNER HST 300 Print 2.0 User's Manual
>Settings
-M-
Recording
-M-
Display 9
***
SET-UP MENU ***
>Check Cd Expiry off
Memory Control
on
Wldr Code Option-M-
Display 10
***
SET-UP MENU ***
Language
-M-
>Date/Time
-M-
Buzzer Volume
-M-
Display 11
***** LANGUAGE *****
>Deutsch
English
Francais
Display 12
EN