screen and the audible signal buzzes continuously. An error has to be
acknowledged by pressing the STOP/RESET key.
5.9
Cooling Time
The cooling time as given in the fitting manufacturer's instructions has
to be respected. If the bar code provided by the fitting manufacturer
contains cooling time data, it will be displayed at the end of the weld-
ing process and will be counted down to zero. This countdown can
be acknowledged and canceled at any time by the STOP/RESET key.
However, note that for that time the pipe fitting joint which is still
warm must not be subjected to an external force. No cooling time is
displayed if the fitting code does not contain any such information.
5.10 Returning to the Start of Parameter Input
After welding is finished, disconnecting the welded fitting from the
unit or pressing the STOP/RESET key will reset the unit back to the
start of entering the welding parameters.
6
Additional Information in the Welding Report
Every welding report saved to system memory, which can be down-
loaded as a PDF report file or in the DataWork format, contains a
number of welding and traceability data that the operator can decide
to enter or not to enter in the set-up menu.
6.1 Entering Preformatted and User-defined Traceability Data
All traceability data enabled in the configuration menu at "Data Re-
cording" (see Sect. 9) have to be entered before the welding process.
The welding unit prompts the user to enter them before entering the
fitting bar code (see Display 2). Depending on what data is entered,
either its repeated input is mandatory (e. g., the welder ID code; see
Sect. 5.2) or previously entered data can be changed and confirmed
or confirmed without changes (e. g. the commission number; see
Sect. 6.2).
The commission number can also be accessed quickly, via a selection
screen, by pressing the ï cursor key (see Display 6), for entering or
changing/confirming it.
6.2
Entering or Changing the Job Number
The commission number input screen is shown by the unit before
welding or accessed by the user in the quick access screen (Display 6).
It can be entered by using the ï, ð, ñ, ò keys or by reading it from
a bar code using the scanner. The maximum length is 32 characters.
Confirm your input by pressing the START/SET key. The job number will
be saved to memory and will appear in the printed welding report.
7
Downloading the Reports
Interface
USB A Interface Port
for connecting USB mass storage media (such as a memory
stick)
The interface port complies with the USB version 2.0 specification (i.e.,
maximum data rate of 480 megabits per second).
10
EN
HÜRNER HST 300 Print 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
***
Recording
>Welder ID Code
Enter Job No.
** Commission No. **
********************
************
****
Display 6
Display 7
Version June 2013