Télécharger Imprimer la page

Installation Of Iso-F Flange - Agilent Technologies TwisTorr 804 FS Mode D'emploi

Publicité

17
Technical Information
Connection of the High Vacuum Flange

Installation of ISO-F Flange

For ISO-F flange connections, fix the two flanges with the high
resistance 12.9 screws as shown in the following figure (a protective
screen can optionally be used).
Figure 61
Use the required number of hex screws:
12 for ISO 200-250 flange
Tighten the screws with a torque of 40 Nm.
TwisTorr 804 FS User Manual / 87-901-052-01
329/344

Publicité