Final works

6.1

Installation check

(
Stop!
Destruction of the digital outputs (X5/A1 … X5/A4).
The digital outputs are not protected against external voltage.
Possible consequences:
ƒ
Protective measures:
ƒ
After completing the installation, the following must be checked:
Wiring for completeness, short−circuit, and earth fault
ƒ
In−phase connection of the mains cable
ƒ
In−phase connection of the motor cable (direction of rotation)
ƒ
If necessary, direction of rotation of the incremental encoder
ƒ
)
Note!
The installation check is followed by commissioning. Further information can
be obtained from the System Manual for the drive controller.
ƒ
ƒ
ƒ
EDKVF9333V DE/EN/FR 7.2
Applying an external voltage to X5/A1 … X5/A4 can damage the digital
outputs. The control card does not work correctly any longer.
Never apply an external voltage to the terminals X5/A1 … X5/A4.
Read the System Manual carefully before you switch on the controller!
Carry out the commissioning steps in accordance with the System Manual!
If you use the "safe standstill" function, check the function of the circuit!