Lenze L-force 9400 Instructions De Montage
Lenze L-force 9400 Instructions De Montage

Lenze L-force 9400 Instructions De Montage

Masquer les pouces Voir aussi pour L-force 9400:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

EDK94AZMP0494
.Z!L
L−force Drives
Montageanleitung
Mounting Instructions
Instructions de montage
9400/i700
E94AZMP0494
Netzfilter
Mains filter
Filtre réseau
49 A
l

Publicité

Table des Matières
loading

Sommaire des Matières pour Lenze L-force 9400

  • Page 1 L−force Drives EDK94AZMP0494 .Z!L Montageanleitung Mounting Instructions Instructions de montage 9400/i700 49 A E94AZMP0494 Netzfilter Mains filter Filtre réseau...
  • Page 2 Lesen Sie zuerst diese Anleitung und die Dokumentation zum Grundgerät, bevor Sie mit den Arbeiten beginnen! Beachten Sie die enthaltenen Sicherheitshinweise. Please read these instructions and the documentation of the standard device before you start working! Observe the safety instructions given therein! Lire le présent fascicule et la documentation relative à...
  • Page 3: Table Des Matières

    Inhalt Über diese Dokumentation ......... Informationen zur Gültigkeit .
  • Page 4: Über Diese Dokumentation

    Qualifiziertes Fachpersonal sind Personen, die für die auszuführenden Tätigkei- ten bei der Aufstellung, Montage, Inbetriebsetzung und dem Betrieb des Pro- dukts über entsprechende Qualifikationen verfügen. Tipp! Informationen und Hilfsmittel rund um die Lenze−Produkte finden Sie im Download−Bereich unter www.lenze.com EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 5: Dokumenthistorie

    Über diese Dokumentation Dokumenthistorie Dokumenthistorie Materialnummer Version Beschreibung .Z!L 05/2019 TD15 Überarbeitung 13556665 07/2018 TD29 Erstausgabe Verwendete Konventionen Informationsart Auszeichnung Beispiele/Hinweise Zahlenschreibweise Dezimaltrennzeichen Punkt Es wird generell der Dezimalpunkt verwendet. Zum Beispiel: 1234.56 Textauszeichnung Programmname » « PC−Software Zum Beispiel: »Engineer«, »Global Drive Control«...
  • Page 6: Verwendete Hinweise

    Über diese Dokumentation Verwendete Hinweise Verwendete Hinweise Um auf Gefahren und wichtige Informationen hinzuweisen, werden in dieser Dokumentation folgende Piktogramme und Signalwörter verwendet: Sicherheitshinweise Aufbau der Sicherheitshinweise: Gefahr! (kennzeichnet die Art und die Schwere der Gefahr) Hinweistext (beschreibt die Gefahr und gibt Hinweise, wie sie vermieden werden kann) Piktogramm und Signalwort Bedeutung...
  • Page 7 Über diese Dokumentation Verwendete Hinweise Spezielle Sicherheitshinweise und Anwendungshinweise Piktogramm und Signalwort Bedeutung Warnings! Sicherheitshinweis oder Anwendungshinweis für den Betrieb nach UL− oder CSA−Anforderungen. Die Maßnahmen sind erforderlich, um die Anforderun- gen nach UL oder CSA zu erfüllen. Warnings! EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 8: Sicherheitshinweise

    Schaltungsausschnitte sind Vorschläge, deren Übertragbarkeit auf die jeweilige Anwendung überprüft werden muss. Für die Eignung der angege- benen Verfahren und Schaltungsvorschläge übernimmt der Hersteller keine Gewähr. Alle Arbeiten mit und an Lenze−Antriebs− und ƒ Automatisierungskomponenten darf nur qualifiziertes Fachpersonal ausführen.
  • Page 9: Restgefahren

    Sicherheitshinweise Restgefahren Restgefahren Gefahr! Gefährliche elektrische Spannung Alle Leistungsanschlüsse führen bis zu 3 Minuten nach Netz−Ausschalten gefährliche elektrische Spannung. Mögliche Folgen: Tod oder schwere Verletzungen beim Berühren der ƒ Leistungsanschlüsse. Schutzmaßnahmen: Vor Arbeiten an den Leistungsanschlüssen Netz abschalten und ƒ mindestens 3 Minuten warten.
  • Page 10 Sicherheitshinweise Restgefahren Stop! Hohes Gerätegewicht Das Gerät ist sehr schwer und muss für die Montage angehoben werden. Mögliche Folgen: Personenschäden, insbesondere Rückenschäden beim Anheben ƒ bzw. Halten des Gerätes Sach− und Personenschäden durch Herunterfallen des Gerätes ƒ Schutzmaßnahmen: Gerät nur mit einer für das Gerätegewicht zugelassenen ƒ...
  • Page 11: Produktbeschreibung

    Produktbeschreibung Lieferumfang Produktbeschreibung Lieferumfang Netzfilter E94AZMP0494 ƒ Montageanleitung ƒ Übersicht X301 T1/T2 X302 NF0494 Pos. Beschreibung PE (Netzanschluss) X301 Netzanschluss L1, L2, L3 X302 Anschlussleitungen zum DC Versorgungsmodul L1’, L2’, L3’, PE T1/T2 Thermokontakt−Anschlussklemmen T1, T2 Typenschild EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 12: Identifikation

    Produktbeschreibung Identifikation Identifikation  Type: SSP94NF002  Typenschlüssel Produktreihe Gerätegeneration Zubehör Typ Netzfilter für Power Supply Bemessungsstrom [A] Spannungsklasse 4 = 230 ... 400/480 V EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 13: Technische Daten

    Technische Daten Allgemeine Daten und Einsatzbedingungen Technische Daten Allgemeine Daten und Einsatzbedingungen Konformität und Approbation Approbation UL508 Industrial Control Equipment, Underwriter Laborato- ries (File−No. E219022) for USA and Canada CSA C22.2 No.14 TP TC 020/2011 Elektromagnetische Eurasische Konformität Verträglichkeit von (TR ZU 020/2011) TR ZU: Technische Regulie- technischen Erzeugnis-...
  • Page 14 Technische Daten Allgemeine Daten und Einsatzbedingungen Umweltbedingungen Klima Lagerung IEC/EN 60721−3−1 1K3 (−25 ... +60 °C) Transport IEC/EN 60721−3−2 2K3 (−25 ... +70 °C) Betrieb IEC/EN 60721−3−3 3K3 (−10 ... +55 °C) Stromreduzierung von +40 ... +55 °C: 2.5 %/°C Aufstellhöhe 0 ...
  • Page 15: Bemessungsdaten

    Technische Daten Bemessungsdaten Bemessungsdaten Netz Spannung Spannungsbereich Frequenzbereich f [Hz] 3/PE AC 180 − 0 % ... 264 + 0 % 45 − 0 % ... 65 + 0 % 3/PE AC 320 − 0 % ... 440 + 0 % 45 −...
  • Page 16: Mechanische Daten

    Technische Daten Mechanische Daten Mechanische Daten NF0494 Abb. 4−1 Abmessungen [mm] Masse [kg] E94AZMP0494 25.5 EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 17: Mechanische Installation

    Mechanische Installation Wichtige Hinweise Mechanische Installation Wichtige Hinweise Der Montageort muss den in den Technischen Daten genannten ƒ Einsatzbedingungen immer entsprechen (¶ 13). Ggf. zusätzliche Maßnahmen ergreifen. Die Montageplatte des Schaltschranks muss folgende Eigenschaften ƒ aufweisen: – elektrisch leitfähig – lackfrei Die mechanischen Verbindungen müssen immer gewährleistet sein.
  • Page 18: Anordnung Der Geräte

    Mechanische Installation Anordnung der Geräte Anordnung der Geräte Verwendung mit 9400 SSP94FF003 Abb. 5−1 Anordnungsprinzip Standard Montage: Nebenbau Montagevariante: Überbau E94AZxPxxxx Filter E94APNExxxx DC Versorgungsmodul 9400 (bis 36 A/18 kW mit Montagesockel E94AZPPxxxx) E94AZEX100 DC Einspeisestelle E94AZPxxxxx Montagesockel Achsmodul 9400 EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 19 Mechanische Installation Anordnung der Geräte Verwendung mit i700 SSP94FF003 S2 Abb. 5−2 Anordnungsprinzip Montage: Nebenbau E94AZxPxxxx Filter (Netzanschluss: unten, Ausgang: oben) E70ACPSxxxx4x DC Versorgungsmodul i700 E70AZEVE001 DC−Klemme i700 (nur bei verteilter Installation) EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 20: Befestigungsraster

    Mechanische Installation Befestigungsraster Befestigungsraster Verwendung mit 9400 Wir empfehlen zur Befestigung der Geräte ein M5−Gewindelochraster in die Montageplatte einzubringen. Durch diese Vorbereitung sind die Geräte einfach zu befestigen. Die Gerätegrößen 1, 2, ... n sind so direkt anreihbar. SSP94NF311 Abb. 5−3 Abmessungen [mm] Lochraster für Montagesockel (Gerätegröße 1 bis 3) Lochraster für andere Gerätegrößen oder Filter im Unterbau (nur Single Drive)
  • Page 21: Montageschritte

    Mechanische Installation Montageschritte Montageschritte Stop! Hohes Gerätegewicht Das Gerät ist sehr schwer und muss für die Montage angehoben werden. Mögliche Folgen: Personenschäden, insbesondere Rückenschäden beim Anheben ƒ bzw. Halten des Gerätes Sach− und Personenschäden durch Herunterfallen des Gerätes ƒ Schutzmaßnahmen: Gerät nur mit einer für das Gerätegewicht zugelassenen ƒ...
  • Page 22 Mechanische Installation Montageschritte Verwendung mit 9400 So gehen Sie bei der Montage vor: 1. Bereiten Sie auf der Montageplatte M5−Gewindebohrungen z. B. gemäß dem Befestigungsraster vor. – Nutzen Sie stets alle vorgegebenen Befestigungspunkte. 2. Schrauben Sie das Filter auf die Montageplatte. –...
  • Page 23: Elektrische Installation

    Elektrische Installation Wichtige Hinweise Elektrische Installation Wichtige Hinweise Die Installation muss ƒ – den in den Technischen Daten genannten Einsatzbedingungen immer entsprechen (¶ 13). – nach EN 60204−1 ausgeführt werden. Bei der Auswahl des Leitungstyps beachten: ƒ – Die verwendeten Leitungen müssen den geforderten Approbationen am Einsatzort entsprechen (z.
  • Page 24 Elektrische Installation Wichtige Hinweise Gefahr! Gefährliche elektrische Spannung Der Ableitstrom gegen Erde (PE) ist > 3.5 mA AC bzw. > 10 mA DC. Mögliche Folgen: Tod oder schwere Verletzungen beim Berühren des Gerätes im ƒ Fehlerfall. Schutzmaßnahmen: Die in der EN 61800−5−1 geforderten Maßnahmen umsetzen. Insbesondere: Festinstallation ƒ...
  • Page 25 Elektrische Installation Wichtige Hinweise Stop! Kein Geräteschutz gegen zu hohe Netzspannung Der Netzeingang ist intern nicht abgesichert. Mögliche Folgen: Zerstörung des Gerätes bei zu hoher Netzspannung. ƒ Schutzmaßnahmen: Beachten Sie die maximal zulässige Netzspannung. ƒ Sichern Sie das Gerät netzseitig fachgerecht gegen ƒ...
  • Page 26: Anschlussplan

    Elektrische Installation Anschlussplan Anschlussplan Verwendung mit 9400 Standardmontage Montagevariante F1...F3 F1...F3 L1 L2 L3 X301 X111 X301 T1 T2 T1 T2 X112 X302 X302 L1 L2 L3 X111 SSP94NF305_0494 SSP94NF305_0494 Abb. 6−1 Schaltungsprinzip E94AZMPxxxx Netzfilter E94APNExxxx DC Versorgungsmodul 9400 F1 ... F3 Sicherungen Netzschütz EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 27 Elektrische Installation Anschlussplan Verwendung mit i700 F1...F3 X302 X100 T1 T2 X301 SSP94NF105 S2 Abb. 6−2 Schaltungsprinzip E94AZRPxxxx Funk−Entstörfilter E70ACPSxxxx4x DC Versorgungsmodul i700 F1 ... F3 Sicherungen Netzschütz EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 28: Anschlussdaten

    Elektrische Installation Anschlussdaten Anschlussdaten Netz Klemme X301 Beschriftung Beschreibung Anschluss der Netzphasen L1, L2, L3 und des Schutzleiters L1 L2 L3 NF0494 Klemmendaten max. Leiterquerschnitt Anzugsmoment [AWG] [Nm] [lb−in] L1, L2, L3 − (M5) 26.5 Grundgerät Leitung X302 Beschriftung Beschreibung L1’...
  • Page 29: Montageschritte

    Elektrische Installation Montageschritte Thermokontakt Klemme Beschriftung Beschreibung Anschluss der Netzphasen L1, L2, L3 und des Schutzleiters SSP94NF306 Klemmendaten max. Leiterquerschnitt Anzugsmoment [AWG] [Nm] [lb−in] T1, T2 0.6 ... 0.8 5.3 ... 7.1 Montageschritte Verwendung mit 9400 So schließen Sie das Filter an: 1.
  • Page 30 Elektrische Installation Montageschritte EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 31 Contents About this documentation ......... Validity information .
  • Page 32: About This Documentation

    Qualified skilled personnel are persons who have the required qualifications to carry out all activities involved in installing, mounting, commissioning, and operating the product. Tip! Information and tools concerning the Lenze products can be found in the download area at www.lenze.com Document history...
  • Page 33: Conventions Used

    About this documentation Conventions used Conventions used Type of information Identification Examples/notes Spelling of numbers Decimal separator Point In general, the decimal point is used. For instance: 1234.56 Text Program name » « PC software For example: »Engineer«, »Global Drive Control« (GDC) EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 34: Notes Used

    About this documentation Notes used Notes used The following pictographs and signal words are used in this documentation to indicate dangers and important information: Safety instructions Structure of safety instructions: Danger! (characterises the type and severity of danger) Note (describes the danger and gives information about how to prevent dangerous situations) Pictograph and signal word Meaning...
  • Page 35 About this documentation Notes used Special safety instructions and application notes Pictograph and signal word Meaning Warnings! Safety note or application note for the operation according to UL or CSA requirements. The measures are required to meet the requirements according to UL or CSA. Warnings! EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 36: Safety Instructions

    The manufacturer does not accept any liability for the suitability of the specified procedures and circuit proposals. Only qualified skilled personnel are permitted to work with or on Lenze ƒ drive and automation components.
  • Page 37: Residual Hazards

    Safety instructions Residual hazards Residual hazards Danger! Dangerous electrical voltage All power terminals remain live for up to three minutes after mains disconnection. Possible consequences: Death or severe injuries when touching the power terminals. ƒ Protective measures: Switch off the power supply and wait for at least three minutes ƒ...
  • Page 38 Safety instructions Residual hazards Stop! Heavy device weight The device is very heavy and must be lifted for the mounting. Possible consequences: Injury to persons, particularly backache when lifting and holding ƒ the device, respectively Injury to persons and damage to material assets due to the ƒ...
  • Page 39: Product Description

    Product description Scope of supply Product description Scope of supply Mains filter E94AZMP0494 ƒ Mounting instructions ƒ Overview X301 T1/T2 X302 NF0494 Pos. Description PE (mains connection) X301 Mains connection L1, L2, L3 X302 Connection cables to the DC power supply module L1’, L2’, L3’, PE T1/T2 Thermal contact terminals T1, T2 Nameplate...
  • Page 40: Identification

    Product description Identification Identification  Type: SSP94NF002  Type code Product range Version Accessories Type of mains filter for power supply Rated current [A] Voltage class 4 = 230 ... 400/480 V EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 41: Technical Data

    Technical data General data and operating conditions Technical data General data and operating conditions Conformity and approval Approval UL508 Industrial Control Equipment, Underwriter Laboratories (File−No. E219022) for USA and Canada CSA C22.2 No.14 TP TC 020/2011 Electromagnetic Eurasian Conformity compatibility of (TR CU 020/2011) TR CU: Technical Regulation technical means...
  • Page 42 Technical data General data and operating conditions Environmental conditions Climate Storage IEC/EN 60721−3−1 1K3 (−25 ... +60 °C) Transport IEC/EN 60721−3−2 2K3 (−25 ... +70 °C) Operation IEC/EN 60721−3−3 3K3 (−10 ... +55 °C) Current derating at +40 ... +55 °C: 2.5 %/°C Site altitude 0 ...
  • Page 43: Rated Data

    Technical data Rated data Rated data Mains Voltage Voltage range Frequency range f [Hz] Lrated Lrated 3/PE AC 180 − 0 % ... 264 + 0 % 45 − 0 % ... 65 + 0 % 3/PE AC 320 − 0 % ... 440 + 0 % 45 −...
  • Page 44: Mechanical Data

    Technical data Mechanical data Mechanical data NF0494 Fig. 4−1 Dimensions [mm] Mass [kg] E94AZMP0494 25.5 EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 45: Mechanical Installation

    Mechanical installation Important notes Mechanical installation Important notes The mounting location must always comply with the operating conditions ƒ specified in the technical data (¶ 41). Take additional measures if necessary. The mounting plate of the control cabinet must have the following ƒ...
  • Page 46: Arrangement Of The Devices

    Mechanical installation Arrangement of the devices Arrangement of the devices Use with 9400 SSP94FF003 Fig. 5−1 Arrangement concept Standard mounting: side mounting Mounting variant: top mounting E94AZxPxxxx Filter E94APNExxxx 9400 DC power supply module (up to 36 A/18 kW with E94AZPPxxxx installation backplane) E94AZEX100 DC input module E94AZPxxxxx...
  • Page 47 Mechanical installation Arrangement of the devices Use with i700 SSP94FF003 S2 Fig. 5−2 Arrangement concept Mounting: side mounting E94AZxPxxxx Filter (mains connection: at the bottom, output: at the top) E70ACPSxxxx4x i700 DC power supply module E70AZEVE001 i700 DC terminal (only in the case of a distributed installation) EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 48: Mounting Grid

    Mechanical installation Mounting grid Mounting grid Use with 9400 We recommend to provide the mounting plate with a grid pattern of M5 threaded holes for attaching the devices. This preparation enables easy attachment of the devices, and the device sizes 1, 2, ... n can thus be mounted directly adjacent to each other.
  • Page 49: Mounting Steps

    Mechanical installation Mounting steps Mounting steps Stop! Heavy device weight The device is very heavy and must be lifted for the mounting. Possible consequences: Injury to persons, particularly backache when lifting and holding ƒ the device, respectively Injury to persons and damage to material assets due to the ƒ...
  • Page 50 Mechanical installation Mounting steps Use with 9400 Proceed as follows for the installation: 1. Prepare M5 threaded holes on the mounting plate, for instance according to the mounting grid. – Always use all mounting points specified. 2. Screw the filter onto the mounting plate. –...
  • Page 51: Electrical Installation

    Electrical installation Important notes Electrical installation Important notes Installation must ƒ – always be in accordance with the operating conditions specified in the Technical data (¶ 41). – be carried out to EN 60204−1. Please observe the following when selecting the cable type: ƒ...
  • Page 52 Electrical installation Important notes Danger! Hazardous electrical voltage The leakage current to earth (PE) is > 3.5 mA AC or > 10 mA DC. Possible consequences: Death or severe injuries when touching the device in the event of ƒ an error. Protective measures: Implement the measures required in EN 61800−5−1.
  • Page 53 Electrical installation Important notes Stop! No device protection if the mains voltage is too high The mains input is not internally fused. Possible consequences: Destruction of the device if the mains voltage is too high. ƒ Protective measures: Observe the maximally permissible mains voltage. ƒ...
  • Page 54: Connection Plan

    Electrical installation Connection plan Connection plan Use with 9400 Standard mounting Mounting variant F1...F3 F1...F3 L1 L2 L3 X301 X111 X301 T1 T2 T1 T2 X112 X302 X302 L1 L2 L3 X111 SSP94NF305_0494 SSP94NF305_0494 Fig. 6−1 Connection concept E94AZMPxxxx Mains filter E94APNExxxx 9400 DC power supply module F1 ...
  • Page 55 Electrical installation Connection plan Use with i700 F1...F3 X302 X100 T1 T2 X301 SSP94NF105 S2 Fig. 6−2 Connection concept E94AZRPxxxx RFI filter E70ACPSxxxx4x i700 DC power supply module F1 ... F3 Fuses Mains contactor EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 56: Connection Data

    Electrical installation Connection data Connection data Mains Terminal X301 Labelling Description Connection of mains phases L1, L2, L3 and PE conductor L1 L2 L3 NF0494 Terminal data Max. conductor cross−section Tightening torque [AWG] [Nm] [lb−in] L1, L2, L3 − (M5) 26.5 Standard device Cable X302...
  • Page 57: Mounting Steps

    Electrical installation Mounting steps Thermal contact Terminal Labelling Description Connection of mains phases L1, L2, L3 and PE conductor SSP94NF306 Terminal data Max. conductor cross−section Tightening torque [AWG] [Nm] [lb−in] T1, T2 0.6 ... 0.8 5.3 ... 7.1 Mounting steps Use with 9400 Proceed as follows to connect the filter: 1.
  • Page 58 Electrical installation Mounting steps EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 59 Sommaire Présentation du document ......... Validité...
  • Page 60: Présentation Du Document

    à leurs activités. Conseil ! Toutes les informations relatives aux produits Lenze peuvent être téléchargées sur notre site à l’adresse suivante : www.Lenze.com Historique du document Numéro de document Version...
  • Page 61: Conventions Utilisées

    Présentation du document Conventions utilisées Conventions utilisées Type d’information Aperçu Exemples/remarques Représentation des chiffres Séparateur décimal Point Le point décimal est généralement utilisé. Exemple : 1234.56 Mise en évidence de textes spéciaux Nom de programme » « Logiciel pour PC Exemple : »Engineer«, »Global Drive Control«...
  • Page 62: Consignes Utilisées

    Présentation du document Consignes utilisées Consignes utilisées Pour indiquer des risques et des informations importantes, la présente documentation utilise les mots et pictogrammes suivants : Consignes de sécurité Présentation des consignes de sécurité Danger ! (Le pictogramme indique le type de risque.) Explication (L’explication décrit le risque et les moyens de l’éviter.) Pictogramme et mot associé...
  • Page 63 Présentation du document Consignes utilisées Consignes de sécurité et d’utilisation spéciales Pictogramme et mot associé Description Avertissements ! Consigne de sécurité ou d’utilisation pour le fonctionnement selon les normes UL ou CSA. Les mesures sont requises pour répondre aux exigences des normes UL ou CSA.
  • Page 64: Consignes De Sécurité

    Les procédures à suivre et les plans de raccordement fournis constituent des recommandations dont l’adéquation avec l’application concernée doit être vérifiée. Lenze n’assumera aucune responsabilité pour les dommages liés à un problème d’adéquation des procédures et plans de raccordements indiqués.
  • Page 65: Avertissements

    Consignes de sécurité Dangers résiduels Dangers résiduels Danger ! Tension électrique dangereuse Les raccordements de puissance sont encore sous tension jusqu’à 3 minutes après la coupure réseau. Risques encourus : Mort ou blessures graves en cas de contact accidentel avec les ƒ...
  • Page 66 Consignes de sécurité Dangers résiduels Stop ! Appareil lourd Cet appareil est très lourd et doit être soulevé pour le montage. Risques encourus : Blessures, notamment lombalgies causées par le fait de soulever ƒ ou de maintenir l’appareil Blessures et dommages matériels causés par une chute de ƒ...
  • Page 67: Description Du Produit

    Description du produit Équipement livré Description du produit Équipement livré> Filtre réseau E94AZMP0494 ƒ Instructions de montage ƒ Présentation générale X301 T1/T2 X302 NF0494 Pos. Description PE (alimentation réseau) X301 Raccordement réseau L1, L2, L3 X302 Câbles de raccordement au module d’alimentation CC L1’, L2’, L3’, PE T1/T2 Bornes contact thermique T1, T2 Plaque signalétique...
  • Page 68: Identification

    Description du produit Identification Identification  Type: SSP94NF002  Codification des types Série d’appareils Génération d’appareils Accessoires Type filtre réseau pour Power Supply Courant assigné [A] Classe de tension 4 = 230 à 400/480 V EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 69: Spécifications Techniques

    Spécifications techniques Caractéristiques générales et conditions d’utilisation Spécifications techniques Caractéristiques générales et conditions d’utilisation Conformité et homologation Homologation UL508 Industrial Control Equipment, Underwriter Laboratories (File−No. E219022) for USA and Canada CSA C22.2 No.14 TP TC 020/2011 Compatibilité Conformité eurasienne électromagnétique des (RT UD 020/2011) RT UD : Règlement équipements...
  • Page 70 Spécifications techniques Caractéristiques générales et conditions d’utilisation Conditions climatiques Classification climatique Stockage CEI/EN 60721−3−1 1K3 (−25 ... +60 °C) Transport CEI/EN 60721−3−2 2K3 (−25 ... +70 °C) Fonctionnement CEI/EN 60721−3−3 3K3 (−10 ... +55 °C) Réduction de courant de +40 ... +55 °C : 2.5 %/°C Altitude 0 ...
  • Page 71: Caractéristiques Assignées

    Spécifications techniques Caractéristiques assignées Caractéristiques assignées Réseau Tension Plage de tension Plage de fréquence f [Hz] 3/PE CA 180 − 0 % ... 264 + 0 % 45 − 0 % ... 65 + 0 % 3/PE CA 320 − 0 % ... 440 + 0 % 45 −...
  • Page 72: Caractéristiques Mécaniques

    Spécifications techniques Caractéristiques mécaniques Caractéristiques mécaniques NF0494 Fig.4−1 Cotes [mm] Poids [kg] E94AZMP0494 25.5 EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 73: Installation Mécanique

    Installation mécanique Remarques importantes Installation mécanique Remarques importantes L’emplacement de montage doit impérativement remplir les conditions ƒ d’utilisation décrites dans les spécifications techniques.(¶ 69). Si nécessaire, prendre des mesures complémentaires. La plaque de montage de l’armoire électrique doit présenter les ƒ...
  • Page 74: Disposition Des Appareils

    Installation mécanique Disposition des appareils Disposition des appareils Avec les appareils série 9400 SSP94FF003 Fig.5−1 Disposition des appareils (principe) Montage standard : latéral Variante de montage : au−dessus E94AZxPxxxx Filtre E94APNExxxx Module d’alimentation CC 9400 ( jusqu’à 36 A/18 kW avec socle de montage E94AZPPxxxx) E94AZEX100 Module d’alimentation CC E94AZPxxxxx...
  • Page 75 Installation mécanique Disposition des appareils Avec les appareils série i700 SSP94FF003 S2 Fig.5−2 Disposition des appareils (principe) Montage : latéral E94AZxPxxxx Filtre (raccordement réseau vers le bas, sortie vers le haut) E70ACPSxxxx4x Module d’alimentation CC i700 E70AZEVE001 Bornier CC i700 (uniquement en cas d’installation répartie) EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 76: Grille De Fixation

    Installation mécanique Grille de fixation Grille de fixation Avec les appareils série 9400 Pour la fixation des appareils, nous recommandons le placement de la grille perforée de trous taraudés M5 sur la plaque de montage. Le montage s’en trouve simplifié. Les tailles d’appareil 1, 2, ... n peuvent ainsi être directement juxtaposées.
  • Page 77: Opérations De Montage

    Installation mécanique Opérations de montage Opérations de montage Stop ! Appareil lourd Cet appareil est très lourd et doit être soulevé pour le montage. Risques encourus : Blessures, notamment lombalgies causées par le fait de soulever ƒ ou de maintenir l’appareil Blessures et dommages matériels causés par une chute de ƒ...
  • Page 78 Installation mécanique Opérations de montage Avec les appareils série 9400 Ordre des opérations de montage 1. Préparer les trous taraudés M5 sur la plaque de montage selon la grille de fixation par exemple. – Utiliser impérativement tous les points de fixation indiqués. 2.
  • Page 79: Installation Électrique

    Installation électrique Remarques importantes Installation électrique Remarques importantes L’installation doit ƒ – toujours respecter les conditions d’utilisation indiquées dans les spécifications techniques (¶ 69) ; – répondre aux exigences de la norme EN 60204−1. Lors du choix du type de câble, tenir compte des points suivants : ƒ...
  • Page 80 Installation électrique Remarques importantes Danger ! Tension électrique dangereuse Le courant de fuite vers la terre (PE) est > 3.5 mA CA ou > 10 mA CC. Risques encourus : Mort ou blessures graves en cas de contact accidentel avec ƒ...
  • Page 81 Installation électrique Remarques importantes Stop ! Appareil non protégé contre une tension réseau trop élevée Il n’y a pas de protection intégrée de l’entrée réseau. Risques encourus : Dommages irréversibles de l’appareil en cas de tension réseau ƒ trop élevée Mesures de protection : Respecter la tension réseau maximale admissible.
  • Page 82: Schéma De Câblage

    Installation électrique Schéma de câblage Schéma de câblage Avec les appareils série 9400 Montage standard Variante de montage F1...F3 F1...F3 L1 L2 L3 X301 X111 X301 T1 T2 T1 T2 X112 X302 X302 L1 L2 L3 X111 SSP94NF305_0494 SSP94NF305_0494 Fig.6−1 Principe de câblage E94AZMPxxxx Filtre réseau...
  • Page 83 Installation électrique Schéma de câblage Avec les appareils série i700 F1...F3 X302 X100 T1 T2 X301 SSP94NF105 S2 Fig.6−2 Principe de câblage E94AZRPxxxx Filtre antiparasite E70ACPSxxxx4x Module d’alimentation CC i700 F1 ... F3 Fusibles Contacteur réseau EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 84: Données De Raccordement

    Installation électrique Données de raccordement Données de raccordement Réseau d’alimentation Borne X301 Marquage Description Connexion des phases réseau L1, L2, L3 et du conducteur de L1 L2 L3 protection PE NF0494 Spécifications pour bornier Section max. de câble Couple de serrage [AWG] [Nm] [lb−in]...
  • Page 85: Opérations De Montage

    Installation électrique Opérations de montage Contact thermique Borne Marquage Description Connexion des phases réseau L1, L2, L3 et du conducteur de protection PE SSP94NF306 Spécifications pour bornier Section max. de câble Couple de serrage [AWG] [Nm] [lb−in] T1, T2 0.6 ... 0.8 5.3 ...
  • Page 86 Installation électrique Opérations de montage EDK94AZMP0494 DE/EN/FR 2.0...
  • Page 88 © 05/2019 Lenze Automation GmbH Service Lenze Service GmbH Postfach 10 13 52, 31763 Hameln Breslauer Straße 3, 32699 Extertal Hans−Lenze−Str. 1, 31855 Aerzen GERMANY GERMANY HR Hannover B 205381 +49 5154 82−0 008000 2446877 (24 h helpline) Ê Ê...

Ce manuel est également adapté pour:

L-force i700E94azmp0494

Table des Matières