9.1
Power supply connection
Phase
Unscrew the cable gland nut and
extract the terminal board from the
Action
connector, releasing it from the
side clips.
Illustration
Phase
Insert the wired terminal board in
the cable gland, securing it with the
Action
side clips. Screw on the locking
nut.
Illustration
ENGLISH
EVOSTA3
1
Rotate the terminal board
through 180°.
4
Connect the wired connector to
the pump, securing it with the
rear hook.
Table 4: Mounting the Evosta3 connector
41
2
Fit nut and connector on the cable.
Strip the wires as indicated in the
figure. Connect the wires to the
terminal board, respecting the
phase, neutral and earth
5