EVOSTA2, EVOSTA3, EVOSTA2 SOL
EVOSTA2 40-70/xxx M230/50-60
EVOSTA2 80/xxx M230/50-60
EVOSTA3 40/xxxM230/50-60
EVOSTA3 60/xxx M230/50-60
EVOSTA3 80/xxx M230/50-60
EVOSTA2 75/xxx SOL
EVOSTA2 105/xxx SOL
EVOSTA2 145/xxx SOL
Table 3: Maximum head (Hmax) and maximum flow rate (Qmax) of EVOSTA2, EVOSTA3, EVOSTA2 SOL circulators
7. MANAGEMENT
7.1
Storage
All the circulators must be stored in a dry covered place, with possibly constant air humidity, free from vibrations and dust. They are
supplied in their original pack in which they must remain until the time of installation. If this is not the case, accurately close the suction
and delivery mouth.
7.2
Transport
Avoid subjecting the products to needless impacts and collisions. To lift and transport the circulator use lifting devices with the aid
of the pallet supplied with it
7.3
Weight
The adhesive plate on the packaging indicates the total weight of the circulator.
8. INSTALLATION – EVOSTA2, EVOSTA3
Always switch off the mains power supply before working on the electrical or mechanical part of the
system. Wait for the warning lights on the control panel to go out before opening the appliance. The
capacitor of the direct current intermediate circuit remains charged with dangerously high voltage even
after the mains power has been turned off.
Only firmly cabled mains connections are admissible. The appliance must be earthed (IEC 536 class 1,
NEC and other applicable standards).
Ensure that the voltage and frequency on the data plate of the EVOSTA2, EVOSTA3 circulator are the same
as those of the power mains.
(if contemplated).
ENGLISH
Hmax [m]
6,9
8
4
6
8
7,5
10,5
14,5
35
Qmax [m
/h]
3
3,6
4,2
2,9
3,6
4,2
4
3,6
3,6