4 OPERATION
4.3.4 Output 1 (Base)
Select the controller output 1 logic signal.
Impulse time selection (PULSE 1)
Set the duration of each impulse and the maximum frequency of the output signal.
Impulse frequency selection (PWM1)
Set the frequency of the logic output signal activation.
ENTER
OUTPUT 1
OUTPUT 2
OUTPUT 2
If the pulse output is provided by a relay; set F1 < 60. (cf § 2.5)
PWM 1
0......9
PULSE 1
E-27-
PH CONTROLLER 8205
ENTER
T1 = 000,0S
ENTER
T1 = 012,3S
ENTER
T1 = 000,0S
T1 = 001,5S
ENTER
000 / MIN
012 / MIN
ENTER
(T1 (s)+0,02 (s)) x F1 < 60
Internal checking of this condition
is provided. If this is not, the
program returns to T1 selection
until complying with the required
condition.
Impulse
Duration
(T1)
0......9
Impulse
Duration
(T1)
0......9
Impulse
Frequency
(F1)
0......9