Installation instructions, only for experts
● The heater sensor must be installed in the sauna cabin above the middle
of the sauna heater. A distance of approx. 15 cm to the sauna cabin ceiling
must be maintained.
● The heater sensor must be attached in a way that ensures it is not affected
by an inflow of air.
● The bench sensor must be installed opposite the heating system. A distance
of approx. 15 cm to the sauna cabin ceiling must be maintained.
4.1. Installing the sauna control unit
Refer to Fig. 1 (page 13).
1. Remove the temperature selector and humidity selector 1 and b.
2. Press the clip lock 6 in lightly using a screwdriver and remove the cover
from the housing.
3. Screw one cross-head screw (20 mm) into the wall of the sauna at
a height of approx. 1.70 m at a distance of up to 7 mm.
4. Hang the sauna control unit onto the cross-head screw using the attach-
ment device c as an aid.
5. Guide the heater, evaporator, power supply and light cables through the
cable bushings 7.
6. Guide the wires through the cable bushings 4.
7. For optional door monitor only:
Guide the wires for the door monitor through the cable bushing 4.
8. Screw two cross-head screws (20 mm) into the lower fastening holes 3
and 8.
9. Ensure that the sauna control unit is fitted securely.