Installation instructions, only for experts
Problem: the E-12 error message appears in the display
Troubleshooting: check the excess temperature fuse
a. Disconnect all sauna control terminals from the mains.
b. Disconnect the red heater sensor wires from terminal TS on
the sauna control unit.
c. Measure the resistance on both ends of the cable.
► The value must be 0 kΩ (continuity).
If the measured values differ, check the wiring and the connection of the respec-
tive sensor.
Problem: the E-P1 or E-P3 error message appears in the display
The following troubleshooting steps must be performed by a certified electrical fitter.
WARNING!
The following tests must be performed with the power supply
switched on. There is a danger of electric shock.
● NEVER touch live parts.
Troubleshooting: perform the calibration as follows:
a. Turn off the control unit. You do not need to completely disconnect
the unit from the mains.
b. Carefully pull off the knobs of the temperature and humidity controller.
c. Remove the housing cover.
d. Turn the two knobs to the maximum setting (as far as they go
to the right).