Instructions for use for the user
While the sauna heater is heating
The cabin temperature is below 40 °C and the cabin door is opened.
► A recurring beep can be heard.
► The message "door" appears in the display 2.
► After the cabin door is closed, the sauna control unit must
be started again.
The cabin temperature is above 40 °C. The door monitor is no longer used
for fire prevention, but as a power-saving feature.
When the cabin door is opened for less than 5 seconds, there is no message.
The cabin door is opened for more than 5 seconds:
► A recurring beep can be heard.
► The control light 3 flashes.
► The sauna heater is switched off.
► The message "door" appears in the display 2.
► After the cabin door is closed, the sauna heater is switched on again,
the beeping stops, and the message "door" disappears.