Sentiotec K3 NEXT Instructions De Montage Et Mode D'emploi page 41

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66
Instructions for installation and use
p. 9/32
The sauna heater will not heat up again until the sauna cabin temperature falls
below the set temperature.
The evaporator operates along with the sauna heater in combi mode. The tem-
perature in the cabin is lower (approx. 40 to 65 °C) than in sauna mode, with the
relative humidity being considerably higher, ranging from 35% to approximately
70%. The maximum humidity level which can be set depends on the temperature
of the sauna. The higher the sauna temperature, the lower the maximum humid-
ity level which can be set.
For safety reasons, the heating period limiter automatically switches off the sauna
control unit after heating for a period of 6 hours.
The K3 Next sauna control unit has a preset time function. The preset time can
be set to increments of 15 minutes. The minimum preset time is 15 minutes. The
maximum preset time totals 23 hours and 45 minutes. Once the preset time has
elapsed, the sauna heater switches on.
EN
WORLD OF WELLNESS

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

K3-9-n

Table des Matières