Installation instructions, only for experts

4.2. Connecting wires

Refer to Fig. 1 (page 13) and die Fig. 5 (page 21).
1. Connect the white wire for the sensor heater to terminal F1 on the terminal
strip 2; it is not necessary to ensure correct polarity.
2. Connect the red wire for the sensor heater to terminal TS on the terminal
strip 2; it is not necessary to ensure correct polarity.
3. Connect the white wire for the bench heater to terminal F2 on the terminal
strip 2; it is not necessary to ensure correct polarity.
4. Connect the heater, evaporator, power supply and light cables to the
terminal strip 9 in accordance with the connection diagram (Fig. 5).
Observe the operating instructions for the respective devices.
5. If the evaporator features an automatic low-water display, then perform
the following step as well:
Remove the wire jumper U1/Wm and connect the wire for the low-water
display.
6. Connect all earth conductors available to the earth conductor panel 5.
7. For optional door monitor only:
Remove the jumper wire from the terminal DR on the terminal strip 2
and connect the wires for the door monitor.
8. Place the cover of the housing on the upper edge of the lower housing
section and swivel the cover of the housing downwards until it engages
audibly.
9. Refit the temperature selector 1 and the humidity selector b. Note the
flat section of the slide-in shaft when fitting.